Representative Image

Behr Labor-Technik Rapid Infrared Digestion Unit InKjel 450 P for 4 x 500 ml Sample Vessels

Max. no. of sample positions

Nominal capacity per position

Type

Specifications

Compare models
HS Code #
90279000
Amperage
8 A
Depth
440 mm
Power supply frequency
50/60 Hz
Max. no. of sample positions
4
Max. voltage
230 V·AC
Nominal capacity per position
500 ml
Power supply
230 V·AC, 50/60 Hz , 8 A
Rated capacity
1500 W
Type
InKjel 450 P
UNSPSC
41104815

$12,810.18

Inc. GST

Available soon

Product description

The Behr Labor-Technik Rapid Infrared Digestion Unit InKjel 450 P is a reliable and efficient laboratory device designed for processing up to 4 sample vessels of 500 ml. Utilizing rapid infrared heating, this unit ensures consistent and high-performance digestion, perfect for Kjeldahl nitrogen analysis and various lab applications.

Key Features:

  • Brand: Behr Labor-Technik
  • Model: InKjel 450 P
  • Capacity: 4 x 500 ml sample vessels
  • Technology: Rapid infrared digestion
  • Application: Suitable for Kjeldahl and other laboratory digestion procedures
  • Packaging: Delivered as a complete unit

This Behr Labor-Technik digestion unit is ideal for laboratories that require rapid, precise, and large-volume sample processing under controlled conditions.

Downloads

Accessories

Accessories for Kjeldahl rapid sample digestors

ProductTypeDescriptionMfr#Part#AvailabilityPrice
SR 3iSample vessel, 250ml, for InKjel*B002179599.843 766In stock$118.84
SR 5Sample vessel 500ml, for K8 B*B003731709.843 751$277.29
AFSAntifoam tabletsB002179369.843 753$824.33
WPNitrogen-free weighing boatsB004411369.843 754$107.52
KJ 500Sample vessel, 500ml, for InKjel*B002181959.843 775$292.38
SR 4Sample vessel 100ml, for InKjel*B002179609.843 750$86.77
EG 4/ 500Vessel holding frame for four 500ml vessels. Component of InKjel 450 M and PB002180859.843 790$713.04
EG 12Vessel holding frame for twelve 250ml vessels. Component of InKjel 1225 M and PB002180879.843 789$984.67
AE 4Fume exhaust manifold for InKjel 450 and 475 (M and P)B002180889.843 792$1,682.62
EG 6Vessel holding frame for six 250ml vessels. Component of InKjel 625 M and PB002180869.843 788$713.04
EG 4/ 750Vessel holding frame for four 750ml vessels. Component of InKjel 475 M and PB002180809.843 791$720.58
KJ 750Sample vessel, 750ml, for InKjel*B002182189.843 776$307.47
AE12Fume exhaust manifold for InKjel 1225 (M and P)B002180909.843 794$2,861.59
AE 6Fume exhaust manifold for InKjel 625 (M and P)B002180899.843 793$1,761.85

Compare similar models

Rapid infrared digestion unit InKjel 450 P for 4 x 500 ml sample vessels

Manufacturer P/N

B00218107

Part Number

9.843 758

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Rapid infrared digestion unit InKjel 1225 for 12 glasses à 250 ml

Manufacturer P/N

B00218106

Part Number

6.233 440

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Rapid infrared digestion unit InKjel 625 P for 6 x 250 ml sample vessels

Manufacturer P/N

B00218105

Part Number

9.843 760

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

6

Rapid infrared digestion unit InKjel 1210 P for 12 reaction vessels of 100 ml, programmable

Manufacturer P/N

B00497540

Part Number

9.843 756

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Rapid infrared digestion unit InKjel 475 P for 4 x 750 ml sample vessels

Manufacturer P/N

B00218108

Part Number

9.843 759

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Frequently asked questions

It is a reliable and efficient laboratory device designed for processing up to 4 sample vessels of 500 ml. Utilizing rapid infrared heating, this unit ensures consistent and high-performance digestion, perfect for Kjeldahl nitrogen analysis and various lab applications.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story