Representative Image

BINDER Constant Climate Chamber, KBF260UL-120V, With Large Temperature And Humidity Range

Brand:BINDER

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Height int.

Int. Dim. (WxDxH)

Int. width

Max. no. of inserts

Max. voltage

Min. voltage

Nominal capacity

Plug type

Power supply

Rated capacity

Type

Weight

Specifications

Compare models
HS Code #
84198998
Depth int.
575 mm
Ext. dim. (WxDxH)
930 x 900 x 1,396 mm
Ext. depth
900 mm
Ext. height
1396 mm
Ext. width
930 mm
Power supply frequency
50/60 Hz
Height int.
695 mm
Int. Dim. (WxDxH)
656 x 575 x 695 mm
Int. width
656 mm
Material inserts
Stainless steel

$42,618.84

Inc. GST

Available soon

Product description

BINDER Constant Climate Chamber, KBF260UL-120V, With Large Temperature And Humidity Range delivers high-precision temperature and humidity control for long-term stability testing in pharmaceutical, biotechnological, and industrial laboratories. The APT.line preheating chamber technology ensures even climate distribution, while a capacitive humidity sensor with responsive steam humidification maintains accurate and stable conditions. With its inverter cooling unit using the climate-neutral refrigerant R-600a, the KBF260UL-120V combines performance with energy efficiency and environmental sustainability, ensuring reliable and compliant operation for ICH stability studies.

Key Features:

  • Brand: BINDER
  • Model: KBF260UL-120V
  • Technology: APT.line preheating chamber for uniform temperature and humidity control
  • Cooling System: Inverter cooling with R-600a climate-neutral refrigerant
  • Humidity Control: Capacitive humidity sensor with responsive steam humidification
  • Material: Stainless-steel inner chamber and racks; metal oxide-coated safety-glass inner doors
  • Controller: Intuitive touchscreen interface with time-segment and real-time programming
  • Safety: Class 3.3 temperature safety device (DIN 12880) with visual and acoustic alarms
  • Connectivity: USB and Ethernet interfaces for data logging and device monitoring
  • Software: Includes BINDER Multi Management Software APT-COM Basic Edition
  • Additional Features: Adjustable fan speed, door heating to prevent condensation, and internal data logger
  • Design: Floor-standing chamber with robust twin casters and front brakes for mobility and stability

Note: Models 260, 470 and 720 can be optionally equipped with LED light modules for ICH photostability or plant-growth testing. Please order light modules separately.

The BINDER Constant Climate Chamber KBF260UL-120V provides reliable, energy-efficient, and precise environmental control, making it ideal for ICH-compliant stability testing and long-term climatic simulations.

Accessories

Shelves for cooling incubators KB/KB PRO and constant climate chambers KBF/KBF PRO

ProductType of insertMaterialMfr#Part#AvailabilityPrice
Insert shelfStainless steel8012-24096.523 274$1,241.40
Insert shelfStainless steel8012-24056.523 340$314.39
Insert shelfStainless steel8012-24076.523 338$635.97
Insert shelfStainless steel8012-24066.523 339$436.55
Insert shelfStainless steel8012-24086.523 337$1,103.06
Insert shelfStainless steel8012-24106.523 270$1,913.29

External water supply

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
External water supply411045128012-25926.523 271$3,628.97

Compare similar models

Constant climate chamber KBF260UL-120V with large temperature and humidity range

Manufacturer P/N

9020-0495

Part Number

4.710 118

Manufacturer

BINDER

Depth int.

575 mm

Constant climate chamber KBF470-230V with large temperature and humidity range

Manufacturer P/N

9020-0480

Part Number

6.523 260

Manufacturer

BINDER

Depth int.

575 mm

Constant climate chamber KBF1600-230V with large temperature and humidity range

Manufacturer P/N

9020-0483

Part Number

6.523 261

Manufacturer

BINDER

Depth int.

847 mm

Constant climate chamber KBF1060UL-120V with large temperature and humidity range

Manufacturer P/N

9020-0498

Part Number

4.710 122

Manufacturer

BINDER

Depth int.

847 mm

Constant climate chamber KBF720-230V with large temperature and humidity range

Manufacturer P/N

9020-0481

Part Number

4.710 119

Manufacturer

BINDER

Depth int.

575 mm

Constant climate chamber KBF1060-230V with large temperature and humidity range

Manufacturer P/N

9020-0482

Part Number

4.710 121

Manufacturer

BINDER

Depth int.

847 mm

Constant climate chamber KBF720UL-120V with large temperature and humidity range

Manufacturer P/N

9020-0497

Part Number

4.710 120

Manufacturer

BINDER

Depth int.

575 mm

Constant climate chamber KBF260-230V with large temperature and humidity range

Manufacturer P/N

9020-0479

Part Number

4.710 117

Manufacturer

BINDER

Depth int.

575 mm

Constant climate chamber KBF130UL-120V with large temperature and humidity range

Manufacturer P/N

9020-0494

Part Number

4.710 116

Manufacturer

BINDER

Depth int.

386 mm

Constant climate chamber KBF130-230V with large temperature and humidity range

Manufacturer P/N

9020-0478

Part Number

4.710 115

Manufacturer

BINDER

Depth int.

386 mm

Frequently asked questions

it delivers high-precision temperature and humidity control for long-term stability testing in pharmaceutical, biotechnological, and industrial laboratories. The APT.line preheating chamber technology ensures even climate distribution, while a capacitive humidity sensor with responsive steam humidification maintains accurate and stable conditions. With its inverter cooling unit using the climate-neutral refrigerant R-600a, the KBF260UL-120V combines performance with energy efficiency and environmental sustainability, ensuring reliable and compliant operation for ICH stability studies.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story