Representative Image

Hellma Half Micro Cuvette 104 QS, 10mm Thickness, Quartz Glass, 1400 µL with PTFE Cover

Brand:Hellma

Capacity

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Int. width

Path length

Type of closure

Type of cuvette

Specifications

Compare models
HS Code #
70171000
Capacity
1400 µl
Ext. dim. (WxDxH)
12.5 x 12.5 x 45 mm
Ext. depth
12.5 mm
Ext. height
45 mm
Ext. width
12.5 mm
Int. width
4 mm
Material
Quartz glass
Material closure
PTFE
Path length
10 mm
Type of closure
Lid

$310.80

Inc. GST

Supplier Stock: 15
Delivery: 2-4 weeks

Product description

The Hellma Half Micro Cuvette 104 QS is designed for precise and reliable measurements in UV-Vis spectroscopy with a smaller sample volume. Made from high-quality quartz glass (Suprasil), this cuvette offers excellent optical clarity, making it ideal for accurate light transmission measurement across a broad wavelength range. With a 10mm path length and a 1400 µL capacity, it's perfect for micro-sample applications. The cuvette comes with a PTFE cover to ensure sample protection and prevent contamination during measurements.

Key Features:

  • Brand: Hellma
  • Material: Quartz Glass (Suprasil) for high optical clarity
  • Capacity: 1400 µL, ideal for smaller sample volumes
  • Path Length: 10mm, suitable for accurate UV-Vis measurements
  • Lid: Comes with a PTFE cover for sample protection
  • Applications: UV-Vis spectroscopy, chemical analysis, and laboratory experiments
  • Wavelength Range: Suitable for a wide range of UV-Vis wavelengths (200-800 nm)

This cuvette is an excellent choice for researchers and laboratory professionals needing precise measurements of small sample volumes in their spectrophotometric analysis. The Hellma Half Micro Cuvette 104 QS ensures high reproducibility and clarity for all your spectroscopy needs.

Compare similar models

Half-micro-cuvette 104-QS, 10mm thickness quartz glass SUPRASIL®, 1400 µl with cover of PTFE

Manufacturer P/N

104-10-40

Part Number

9.144 460

Manufacturer

Hellma

Capacity

1400 µl

Half-micro-cuvette 108-QS, 10mm thickness quartz glass SUPRASIL®, 1000 µl with cover of PTFE

Manufacturer P/N

108-000-10-40

Part Number

6.250 017

Manufacturer

Hellma

Capacity

1000 µl

Micro-cuvette 104.002-QS, 10mm thickness quartz glass SUPRASIL®, 700 µl with cover of PTFE

Manufacturer P/N

104-002-10-40

Part Number

9.144 751

Manufacturer

Hellma

Capacity

700 µl

Micro-cuvette 115 QS, 10mm thickness quartz glass SUPRASIL®, 400 µl with cover of PTFE

Manufacturer P/N

115-10-40

Part Number

9.144 758

Manufacturer

Hellma

Capacity

400 µl

Micro-cuvette 108.002-QS, 10mm thickness quartz glass SUPRASIL®, 500 µl with cover of PTFE

Manufacturer P/N

108-002-10-40

Part Number

6.084 722

Manufacturer

Hellma

Capacity

500 µl

Half-micro-cuvette 104-QS, 50mm thickness quartz glass SUPRASIL®, 7000 µl with cover of PTFE

Manufacturer P/N

104-50-40

Part Number

9.144 465

Manufacturer

Hellma

Capacity

7000 µl

Half-micro-cuvette 114-QS, 10mm thickness quartz glass SUPRASIL®, 1400 µl, PTFE stopper

Manufacturer P/N

114-10-40

Part Number

9.144 730

Manufacturer

Hellma

Capacity

1400 µl

More items to explore

Cells for absorption measurement, UV-range, black side walls and base

ProductType of closureType of cuvetteMfr#Part#AvailabilityPrice
LidMicro108002B-10-406.076 641$835.38
StopperSemi-Micro114B-10-409.144 372$860.53
LidMicro115B-10-409.144 385$860.53
LidSemi-Micro104-B-10-409.144 490$547.94
LidMicro104002B-10-409.144 756$632.38
LidSemi-Micro108B-10-406.800 224$662.92

Frequently asked questions

It is designed for precise and reliable measurements in UV-Vis spectroscopy with a smaller sample volume. Made from high-quality quartz glass (Suprasil), this cuvette offers excellent optical clarity, making it ideal for accurate light transmission measurement across a broad wavelength range. With a 10mm path length and a 1400 µL capacity, it's perfect for micro-sample applications. The cuvette comes with a PTFE cover to ensure sample protection and prevent contamination during measurements.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story