Representative Image

ISOLAB Adapter GL 14, Cone NS 14/23 for Thermometer, Diameter 6-8 mm, Straight Form, BORO 3.3

Brand:ISOLAB

Cone[s]

Specifications

Compare models
HS Code #
70172000
Bore
8 mm
Cone[s]
NS 14/23
Material
Boro 3.3
Standard
DIN 12257
Thread
GL 14
UNSPSC
41104812

$23.35

Inc. GST

Supplier Stock: 67
Delivery: 2-4 weeks

Product description

The ISOLAB Laborgeräte Adapter GL 14, Cone NS 14/23 for Thermometer, Diameter 6-8 mm, Straight Form, BORO 3.3, is designed for securely holding Thermometers in laboratory setups. Made from high-quality BORO 3.3 glass, this adapter offers excellent chemical resistance and durability. The straight form and precise dimensions (diameter 6-8 mm) ensure a secure fit for Thermometers, while the GL 14 socket and NS 14/23 cone design provide compatibility with other laboratory glassware. Ideal for laboratory applications requiring precise temperature measurements and secure placement of Thermometers.

Key Features:

  • Brand: ISOLAB Laborgeräte
  • Material: BORO 3.3 glass for durability and chemical resistance
  • Design: GL 14 socket, Cone NS 14/23, straight form for secure Thermometer placement
  • Diameter: 6-8 mm for Thermometer compatibility
  • Application: Ideal for securing Thermometers in laboratory experiments requiring precise temperature measurement

This adapter is an essential tool for laboratories that require secure placement of Thermometers for accurate temperature readings in various scientific applications.

Accessories

Sleeves, cone joint, PTFE

ProductTemperature resistanceMaterialMfr#Part#AvailabilityPrice
-200 ... 250 °CPTFEH 933-039.011 642In stock$14.37
-200 ... 250 °CPTFEH 933-069.011 645In stock$19.76
-200 ... 250 °CPTFEH 933-099.011 647In stock$62.88
-200 ... 250 °CPTFEH 933-049.011 643$21.56
-200 ... 250 °CPTFEH 933-059.011 644$25.15

Sleeves with ribs, PTFE

ProductTemperature resistanceMaterialMfr#Part#AvailabilityPrice
-200 ... 250 °CPTFEH 930-049.011 655In stock$16.17
-200 ... 250 °CPTFEH 930-059.011 656In stock$17.97
-200 ... 250 °CPTFEH 930-069.011 657In stock$21.56
-200 ... 250 °CPTFEH 930-079.011 658In stock$21.56
-200 ... 250 °CPTFEH 930-109.011 660In stock$23.35
-200 ... 250 °CPTFEH 930-029.011 652In stock$16.17
-200 ... 250 °CPTFEH 930-07 VE=104.667 522In stock$79.05
-200 ... 250 °CPTFEH 930-10 VE=54.667 523In stock$116.77
-200 ... 250 °CPTFEH 930-04 VE=104.667 519In stock$53.90
-200 ... 250 °CPTFEH 930-039.011 653In stock$14.37
-200 ... 250 °CPTFEH 930-139.011 661$102.40
-200 ... 250 °CPTFEH 930-089.011 659$23.35
-200 ... 250 °CPTFEH 930-149.011 662$186.84
-200 ... 250 °CPTFEH 930-06 VE=104.667 521$77.25
-200 ... 250 °CPTFEH 930-05 VE=104.667 520$64.67
-200 ... 250 °CPTFEH 930-019.011 651$10.78

Compare similar models

Adapter GL 14, cone NS 14/23 for thermometer diameter 6-8 mm, straight form boro 3.3

Manufacturer P/N

065.21.014

Part Number

4.008 360

Manufacturer

ISOLAB

Cone[s]

NS 14/23

Adapter GL 14, cone NS 29/32 for thermometer 6-8 mm Ø, straight form, Boro 3.3

Manufacturer P/N

065.21.029

Part Number

6.244 589

Manufacturer

ISOLAB

Cone[s]

NS 29/32

More items to explore

Screwthread tubes for glassblowers, DURAN® tubing

ProductMaterialLengthMfr#Part#AvailabilityPrice
DURAN® tubing120 mm013000149.209 714In stock$10.78
DURAN® tubing140 mm013000329.209 732In stock$12.58
DURAN® tubing100 mm013000189.209 718In stock$12.58
DURAN® tubing180 mm013000459.209 735In stock$41.32
DURAN® tubing100 mm013000259.209 725In stock$21.56

Frequently asked questions

It is designed for securely holding Thermometers in laboratory setups. Made from high-quality BORO 3.3 glass, this adapter offers excellent chemical resistance and durability. The straight form and precise dimensions (diameter 6-8 mm) ensure a secure fit for Thermometers, while the GL 14 socket and NS 14/23 cone design provide compatibility with other laboratory glassware. Ideal for laboratory applications requiring precise temperature measurements and secure placement of Thermometers.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story