Representative Image

Macherey-Nagel Capillary Column Optima 17, ID 0.25 mm, Film Thickness 0.25 µm, Length 50 m

Film thickness

Int. Ø

Length

Max. temperature programme

Temperature max. isotherm

Specifications

Compare models
Film thickness
0.25 µm
Int. Ø
0.25 mm
Length
50 m
Material column
Quartz glass
Max. temperature programme
320 °C
Polarity
Mid-polar
Temperature max. isotherm
300 °C
UNSPSC
41115710
USP listing
G3

$2,321.16

Inc. GST

Available soon

Product description

The Macherey-Nagel Capillary Column Optima 17 is designed for high-precision gas chromatography (GC) applications. With an internal diameter of 0.25 mm, film thickness of 0.25 µm, and a length of 50 meters, this column provides excellent separation and resolution for a wide range of compounds. Ideal for the analysis of hydrocarbons, environmental samples, and volatile organic compounds (VOCs), the Optima 17 offers optimal thermal stability and minimal bleeding, ensuring reliable results over extended use.

Key Features:

  • Brand: Macherey-Nagel
  • Type: Optima 17 capillary column
  • ID: 0.25 mm
  • Film Thickness: 0.25 µm
  • Length: 50 m
  • Application: GC analysis of hydrocarbons and VOCs

Macherey-Nagel Optima 17 capillary columns deliver exceptional performance, offering high sensitivity and separation efficiency for demanding analytical applications.

Compare similar models

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726022.50

Part Number

4.003 028

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726022.30

Part Number

4.003 027

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726067.30

Part Number

4.003 047

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726351.25

Part Number

4.003 112

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 60 m

Manufacturer P/N

726067.60

Part Number

4.003 049

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m

Manufacturer P/N

726757.30

Part Number

4.003 195

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726351.30

Part Number

4.003 113

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.53 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726747.30

Part Number

4.003 192

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 60 m

Manufacturer P/N

726742.60

Part Number

4.003 184

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 25 m

Manufacturer P/N

726757.25

Part Number

4.003 194

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726351.50

Part Number

4.003 114

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.15 µm length: 30 m

Manufacturer P/N

726755.30

Part Number

4.003 193

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 25 m

Manufacturer P/N

726067.25

Part Number

4.003 046

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 30 m

Manufacturer P/N

726742.30

Part Number

4.003 182

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 25 m

Manufacturer P/N

726742.25

Part Number

4.003 181

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.10 mm, film thickness: 0.1 µm length: 10 m

Manufacturer P/N

726848.10

Part Number

4.003 236

Manufacturer

Macherey-Nagel

Film thickness

0.10 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726022.25

Part Number

4.003 026

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 50 m

Manufacturer P/N

726742.50

Part Number

4.003 183

Manufacturer

Macherey-Nagel

Film thickness

0.15 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726022.60

Part Number

4.003 029

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726351.60

Part Number

4.003 115

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 60 m

Manufacturer P/N

726744.60

Part Number

4.003 188

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.5 µm length: 50 m

Manufacturer P/N

726067.50

Part Number

4.003 048

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 25 m

Manufacturer P/N

726744.25

Part Number

4.003 185

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 50 m

Manufacturer P/N

726744.50

Part Number

4.003 187

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 50 m

Manufacturer P/N

726757.50

Part Number

4.003 196

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.53 mm, film thickness: 1 µm length: 25 m

Manufacturer P/N

726747.25

Part Number

4.003 191

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.35 µm length: 60 m

Manufacturer P/N

726757.60

Part Number

4.003 197

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-17 ID: 0.32 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726744.30

Part Number

4.003 186

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Frequently asked questions

It is designed for high-precision gas chromatography (GC) applications. With an internal diameter of 0.25 mm, film thickness of 0.25 µm, and a length of 50 meters, this column provides excellent separation and resolution for a wide range of compounds. Ideal for the analysis of hydrocarbons, environmental samples, and volatile organic compounds (VOCs), the Optima 17 offers optimal thermal stability and minimal bleeding, ensuring reliable results over extended use.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

1 min read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

1 min read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

1 min read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story

$2,321.16

Inc. GST