Representative Image

Macherey-Nagel Chromabond Columns Florisil, 6 mL Volume, 1000 mg Sorbent, PP with PE Filter Elements, Packed in 5 Bags with 50 pcs

Package

Package capacity

Specifications

Compare models
Base material
Magnesium silicate
Endcapped
No
Filter element material
PE
No. of packages
5
Package
5 x Bag of 50 pcs
Package capacity
50 pcs
Particle size
150 ... 250 µm
Particle type
Fully porous

$2,021.72

Inc. GST

Available soon

Product description

The Macherey-Nagel Chromabond Columns Florisil, with a 6 mL volume and 1000 mg of sorbent, are designed for highly efficient solid-phase extraction (SPE) processes, especially in sample purification and analysis. These columns feature a high-performance Florisil sorbent, known for its excellent retention and separation capabilities. Made from polypropylene (PP), the columns are equipped with polyethylene (PE) filter elements to prevent clogging, ensuring smooth filtration. This pack contains 5 bags with 50 columns, perfect for large-scale laboratory workflows and high-throughput testing.

Key Features:

  • Brand: Macherey-Nagel
  • Column Volume: 6 mL
  • Sorbent Content: 1000 mg Florisil sorbent for efficient extraction
  • Material: Polypropylene (PP) with polyethylene (PE) filter elements
  • Packaging: Packed in 5 bags, each containing 50 columns (total 250 columns)
  • Applications: Ideal for solid-phase extraction (SPE) in analytical and preparative procedures

Macherey-Nagel Chromabond Columns Florisil are essential for laboratories requiring precise and reliable SPE columns with excellent separation power and capacity for handling large volumes of samples.

Downloads

Compare similar models

CHROMABOND columns Florisil BIGpack volume: 6 ml, content of sorbent: 1000 mg material: PP, with PE-filterelements packed in 5 bags with 50 pcs.

Manufacturer P/N

730082.250

Part Number

4.003 489

Manufacturer

Macherey-Nagel

No. of packages

5

CHROMABOND columns Florisil volume: 3 ml, content of sorbent: 200 mg material: PP, with PE-filterelements pack of 50

Manufacturer P/N

730457

Part Number

4.003 624

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns Florisil volume: 3 ml, content of sorbent: 500 mg material: PP, with PE-filterelements pack of 50

Manufacturer P/N

730081

Part Number

4.003 488

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns Florisil volumne: 6 ml, content of sorbent: 500 mg material: PP, with PE-filterelements pack of 30

Manufacturer P/N

730238

Part Number

4.003 557

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns Florisil volume: 6 ml, content of sorbent: 1000 ml PP, with PE-filterelements pack of 30

Manufacturer P/N

730082

Part Number

6.224 842

Manufacturer

Macherey-Nagel

No. of packages

-

More items to explore

CHROMABOND® Florisil®, glass columns

ProductParticle typePackage capacityMfr#Part#AvailabilityPrice
Fully porous30 pcs730082G4.003 490$579.40

Frequently asked questions

It are designed for highly efficient solid-phase extraction (SPE) processes, especially in sample purification and analysis. These columns feature a high-performance Florisil sorbent, known for its excellent retention and separation capabilities. Made from polypropylene (PP), the columns are equipped with polyethylene (PE) filter elements to prevent clogging, ensuring smooth filtration. This pack contains 5 bags with 50 columns, perfect for large-scale laboratory workflows and high-throughput testing.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

1 min read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

1 min read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

1 min read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story

$2,021.72

Inc. GST