Representative Image

SI Analytics Viscometer Ubbelohde 530-30, Not Calibrated for Automatic Measurement, Capillary No. III, Constant K 1

Constant

Int. Ø

Max. measured value

Measured range

Min. measured value

No. of capillary

Type

Specifications

Compare models
HS Code #
90279000
Calibration
No
Capacity
15 ... 20 ml
Constant
1
Int. Ø
2.01 mm
Length
290 mm
Max. measured value
1000 mm²/s
Measured range
100 ... 1,000 mm²/s
Min. measured value
100 mm²/s
No. of capillary
III
Standard
ISO 3105, DIN 51562

$675.49

Inc. GST

Available soon

Product description

The SI Analytics Viscometer Ubbelohde 530-30 is built for accurate manual viscosity measurements, featuring a capillary No. III with a constant K of 1. This model is not calibrated for automatic measurement, making it ideal for laboratories that require reliable manual viscosity testing. It provides dependable performance in accordance with ISO/DIN standards, ensuring precision and consistency for all viscosity testing needs.

Key Features:

  • Brand: SI Analytics
  • Model: Ubbelohde 530-30
  • Capillary: No. III
  • Constant: K 1
  • Calibration: Not calibrated for automatic measurement
  • Application: Ideal for manual viscosity testing in laboratories

This viscometer provides reliable and accurate viscosity measurements, making it an essential tool for laboratories performing manual viscosity testing and calibration as required.

Downloads

Accessories

Viscometer holders

ProductTypeMaterialMfr#Part#AvailabilityPrice
053 92Stainless steel2854050439.268 790$555.12

Viscometer heating jacket

ProductTypeDescriptionMfr#Part#AvailabilityPrice
577 00Viscometer heating jacket2854055089.269 420$1,719.27

Compare similar models

Viscometer Ubbelohde 530 30, not calibrated, for automatic measurement capillary no. III, constant K = 1

Manufacturer P/N

285400361

Part Number

9.268 330

Manufacturer

SI Analytics

Constant

1

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic

Manufacturer P/N

285400312

Part Number

9.268 301

Manufacturer

SI Analytics

Constant

0.005

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic constant 0,003 K,meas.range 0,5 - 3 mm²/sec

Manufacturer P/N

285400304

Part Number

9.268 303

Manufacturer

SI Analytics

Constant

0.003

Viscometer Ubbelohde 530 10, not calibrated, for automatic measurement capillary no. I, constant K = 0.01

Manufacturer P/N

285400329

Part Number

9.268 310

Manufacturer

SI Analytics

Constant

0.01

Viscometer Ubbelohde 530 13, not calibrated, for automatic measurement capillary no. Ic, constant K = 0.03

Manufacturer P/N

285400337

Part Number

9.268 313

Manufacturer

SI Analytics

Constant

0.03

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic constant 0,1 K,meas.range 10 - 100 mm²/sec

Manufacturer P/N

285400345

Part Number

9.268 320

Manufacturer

SI Analytics

Constant

0.1

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic constant 0,3 K,meas.range 30 - 300 mm²/sec

Manufacturer P/N

285400353

Part Number

9.268 323

Manufacturer

SI Analytics

Constant

0.3

Viscometer Ubbelohde 530 40, not calibrated, for automatic measurement capillary no. IV, constant K = 10

Manufacturer P/N

285400386

Part Number

9.268 340

Manufacturer

SI Analytics

Constant

10

Viscometer Ubbelohde 530 33, not calibrated, for automatic measurement capillary no. IIIc, constant K = 3

Manufacturer P/N

285400378

Part Number

9.268 333

Manufacturer

SI Analytics

Constant

3

Ubbelohde viscometer 53 011 (DIN) Not calibrated Capillary No. Ia, Constant K = 0.05

Manufacturer P/N

285400338

Part Number

7.984 645

Manufacturer

SI Analytics

Constant

0.05

Ubbelohde viscometer 530 21 (DIN), not calibrated

Manufacturer P/N

285400350

Part Number

6.521 031

Manufacturer

SI Analytics

Constant

0.5

Ubbelohde viscometer 530 31 Not calibrated

Manufacturer P/N

285400370

Part Number

4.711 075

Manufacturer

SI Analytics

Constant

5

More items to explore

Viscometers Ubbelohde, glass, kinematic

ProductTypeType of capillary viscometerMfr#Part#AvailabilityPrice
501 10Ubbelohde2854000379.268 110In stock$1,067.13
501 20Ubbelohde2854000619.268 120In stock$1,067.13
501 13Ubbelohde2854000459.268 113In stock$1,067.13
501 00Ubbelohde2854000049.268 100$1,106.66
501 01Ubbelohde2854000299.268 101$1,067.13
532 11Ubbelohde2854001727.023 177$1,067.13
501 30Ubbelohde2854000949.268 130$1,067.13
501 21Ubbelohde2854000869.268 121$1,067.13
501 31Ubbelohde2854001159.268 131$1,067.13
501 23Ubbelohde2854000789.268 123$1,067.13
532 10Ubbelohde2854002269.268 210$1,067.13
501 03Ubbelohde2854000129.268 103$1,067.13
532 21Ubbelohde2854001897.023 178$1,067.13
532 31Ubbelohde2854001977.023 179$1,067.13
532 40Ubbelohde2854002839.268 240$1,067.13
532 30Ubbelohde2854002679.268 230$1,067.13
532 03Ubbelohde2854002019.268 203$1,067.13
532 13Ubbelohde2854002349.268 213$1,067.13
532 00Ubbelohde2854001647.023 176$1,106.66
501 11Ubbelohde2854000539.268 111$1,067.13
532 23Ubbelohde2854002599.268 223$1,067.13
501 40Ubbelohde2854001239.268 140$1,067.13
501 33Ubbelohde2854001079.268 133$1,067.13
532 20Ubbelohde2854002429.268 220$1,067.13
532 01Ubbelohde2854002189.268 201$1,067.13
532 33Ubbelohde2854002759.268 233$1,067.13

Frequently asked questions

It is built for accurate manual viscosity measurements, featuring a capillary No. III with a constant K of 1. This model is not calibrated for automatic measurement, making it ideal for laboratories that require reliable manual viscosity testing. It provides dependable performance in accordance with ISO/DIN standards, ensuring precision and consistency for all viscosity testing needs.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story