Representative Image

Stakpure Ultra Pure Water System OmniaPure-W xs touch, UV-TOC/UF

Brand:stakpure

Type

Specifications

Compare models
HS Code #
84212100
Depth
310 mm
Dimensions (WxDxH)
240 x 310 x 415 mm
Power supply frequency
50/60 Hz
Height
415 mm
Max. pressure
6 bar
Max. voltage
240 V
Min. pressure
1 bar
Min. voltage
90 V
Power supply
90 ... 240 V, 50/60 Hz
Pressure
1 ... 6 bar

$20,130.01

Inc. GST

Available soon

Product description

The Stakpure Ultra Pure Water System OmniaPure-W xs touch, UV-TOC/UF is designed for advanced laboratory applications requiring the highest water purity standards. Featuring integrated UV and TOC/UF modules, this system delivers reliable performance and ensures consistent ultra-pure water quality. The intuitive xs touch interface provides ease of use and precise control, making it ideal for analytical and life science applications. The under-bench version saves valuable laboratory space, while the external OptiFill® touch dispenser and monitoring unit can be conveniently mounted on the wall.

Key Features:

  • Brand: Stakpure
  • Model: OmniaPure-W xs touch
  • Technology: UV-TOC/UF modules for ultra-pure water generation
  • Interface: User-friendly xs touch screen
  • Application: Suitable for analytical and life science laboratory use
  • Installation: Under-bench system with external wall-mounted dispenser and monitoring unit

Scope of Supply:

  • Ultra pure water system (under-bench version)
  • Pre-treatment cartridge
  • Ultra pure water cartridge
  • Sterile filter capsule (0.2 µm)
  • External OptiFill® touch dispenser and monitoring unit

The Stakpure OmniaPure-W xs touch UV-TOC/UF system offers a compact, reliable, and high-performance solution for laboratories that demand top-tier water quality.

Downloads

Accessories

Accessories for Ultra pure water systems OmniaPure / OmniaTap / OmniaLab ED

ProductDescriptionForMfr#Part#AvailabilityPrice
Pre-treatment unit OmniTap/Lab - 10"OmniaTap / OmniaTap xs / OmniaLab ED192000216.272 154$813.82
UV tank disinfection unit Omnia 254OmniaLab ED192000506.272 160$1,491.11
UV unit for TOC reduction Omnia 185OmniaLab ED192000526.272 162$3,271.46
Wall mounting OmniaOmniaPure / OmniaTap192003006.272 142$513.80
Docking tank 100 lOmniaLab ED192001006.272 165$3,634.36
Wall mounting Omnia xsOmniaPure xs / OmniaTap xs192003054.686 064$513.80
Pump station OmniaOmniaPure xs165800004.686 056$2,549.26
Volume dosing Omnia xs basicOmniaPure xs basic / OmniaTap xs basic 5192005004.686 065$932.39

Consumables for ultra pure water systems OmniaPure / OmniaTap / OmniaLabED

ProductDescriptionForMfr#Part#AvailabilityPrice
Pure water cartridge Omnia 055OmniaPure / OmniaTap / OmniaLab ED192000036.272 137In stock$1,176.72
UF ultra filtration BIGOmniaPure / OmniaPure xs / OmniaTap / OmniaTap xs190000506.272 141$2,319.31
Sterile filter capsule 0.2 µmOmniaPure / OmniaPure xs / OmniaTap / OmniaTap xs / OmniaLab ED191003006.272 138$468.89
Bio end filterOmniaPure / OmniaPure xs / OmniaTap / OmniaTap xs / OmniaLab ED191021006.272 139$792.27
Pre-treatment cartridge OmniaPureOmniaPure192000026.272 136$664.71
Pure water cartridge Omnia 067OmniaLab ED192000046.272 159$813.82
RO cartridge OmniaTap 6OmniaTap 6192000056.272 151$813.82
RO cartridge OmniaTap 12OmniaTap 12192000106.272 152$1,176.72
UV flow disinfection Omnia 254OmniaLab ED192000516.272 161$4,157.15
Replacement UV lamp Omnia 185OmniaPure / OmniaTap / OmniaLab ED192000556.272 140$891.07
Disinfection kit OmniaOmniaPure / OmniaTap192000566.272 143$574.89
CO 2 absorber and tank venting filterOmniaLab ED195002006.272 166$781.49
Sterile tank venting filterOmniaLab ED195003006.272 167$646.75
Sterile tank venting filterOmniaTap / OmniaTap xs195004006.272 153$282.05
Replacement UV lamp for tank disinfectionOmniaLab ED192000536.272 163$468.89
Replacement UV lamp for flow disinfection Omnia 254OmniaLab ED192000546.272 164$603.63
Pre-treatment cartridge OmniaPure xsOmniaPure xs192001024.686 062$664.71
Ultra pure water cartridge Omnia xs 055OmniaPure xs / OmniaTap xs192001034.686 063$1,176.72
Replacement UV lamp Omnia xs 185OmniaPure xs / OmniaTap xs191002004.686 057$860.53
Disinfection kit Omnia xsOmniaPure xs / OmniaTap xs192000914.686 061$688.07
Disinfection cartridge Omnia xsOmniaPure xs / OmniaTap xs192000904.686 060$574.89
RO cartridge OmniaTap xs 5OmniaTap xs basic 5192000074.686 058$758.13
RO cartridge OmniaTap xs 8OmniaTap xs touch 8192000084.686 059$874.91

Compare similar models

Ultra pure water system OmniaPure-W xs touch UV-TOC/UF

Manufacturer P/N

18100015

Part Number

4.686 071

Manufacturer

stakpure

Type

OmniaPure-W xs touch UV-TOC/UF

Ultra pure water system OmniaPure-W xs touch UV-TOC

Manufacturer P/N

18100014

Part Number

4.686 070

Manufacturer

stakpure

Type

OmniaPure-W xs touch UV-TOC

More items to explore

Ultra pure water system OmniaPure xstouch

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
OmniaPure xs touch UV-TOCMains connection181000044.686 068$15,956.69
OmniaPure xs touch UV-TOC/UFMains connection181000054.686 069$17,354.38

Ultra pure water system OmniaPure xstouch, under-bench version with OptiFilltouch bench dispenser

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
OmniaPure-T xs touch UV-TOC/UFMains connection181000254.686 073$20,848.61
OmniaPure-T xs touch UV-TOCMains connection181000244.686 072$19,470.68

Frequently asked questions

It is designed for advanced laboratory applications requiring the highest water purity standards. Featuring integrated UV and TOC/UF modules, this system delivers reliable performance and ensures consistent ultra-pure water quality. The intuitive xs touch interface provides ease of use and precise control, making it ideal for analytical and life science applications. The under-bench version saves valuable laboratory space, while the external OptiFill® touch dispenser and monitoring unit can be conveniently mounted on the wall.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story