Representative Image

Trajan Scientific Deactivated Fused Silica Tubing, 430 µm OD x 320 µm ID x 2 m Length

Ext. Ø

Int. Ø

Length

Specifications

Compare models
HS Code #
70171000
Ext. Ø
0.43 mm
Int. Ø
0.32 mm
Length
2 m
Material
Quartz glass
UNSPSC
41105108

$137.30

Inc. GST

Available soon

Product description

The Trajan Scientific Deactivated Fused Silica Tubing features a 430 µm outer diameter, 320 µm inner diameter, and a 2-meter length—ideal for accurate and low-interaction sample transport. Its deactivated inner surface minimizes analyte adsorption, making it suitable for sensitive chromatographic and analytical applications.

Key Features:

  • Brand: Trajan Scientific
  • Outer Diameter: 430 µm
  • Inner Diameter: 320 µm
  • Length: 2 meters
  • Material: Deactivated fused silica
  • Application: Precision sample transfer for chromatography and analytical workflows

This tubing is essential for laboratories demanding high purity and minimal sample loss in micro-scale fluid systems.

Compare similar models

Deactivated Fused Silica Tubing 430 µm OD x 320 µm ID x 2 mLength

Manufacturer P/N

0624470

Part Number

6.490 945

Manufacturer

Trajan Scientific

Ext. Ø

0.43 mm

Capillary 5m x 530µm/680µm

Manufacturer P/N

062448

Part Number

6.284 960

Manufacturer

Trajan Scientific

Ext. Ø

0.68 mm

Tubing 5m x 150µm/220µm

Manufacturer P/N

0624461

Part Number

6.321 006

Manufacturer

Trajan Scientific

Ext. Ø

0.22 mm

Methyl deactivated capillary 2VSD/050 0.050 i.d.

Manufacturer P/N

062444

Part Number

6.050 232

Manufacturer

Trajan Scientific

Ext. Ø

0.22 mm

Methyl deactivated Fusedsilica capillary tube length: 10 m, ID: 0.530 mm

Manufacturer P/N

064033

Part Number

7.612 476

Manufacturer

Trajan Scientific

Ext. Ø

0.68 mm

Tubing 2m x 420µm/550µm

Manufacturer P/N

0624477

Part Number

6.322 813

Manufacturer

Trajan Scientific

Ext. Ø

0.55 mm

Desactivated Silica Capillary tubing ID 0,32 mm, length 25m

Manufacturer P/N

0624473

Part Number

7.671 699

Manufacturer

Trajan Scientific

Ext. Ø

0.43 mm

Desactivated silica capillary ID 0.32 mm

Manufacturer P/N

0624471

Part Number

6.059 981

Manufacturer

Trajan Scientific

Ext. Ø

0.43 mm

Tubing 2m x 50µm/363µm

Manufacturer P/N

06244503

Part Number

7.671 384

Manufacturer

Trajan Scientific

Ext. Ø

0.363 mm

Deactivated Fused Silica Tubing 363 µm OD x 250 µm ID x 5 m Length

Manufacturer P/N

0624432

Part Number

6.327 870

Manufacturer

Trajan Scientific

Ext. Ø

0.363 mm

Fused silica tube 285µm OD x 25µm ID x 2m length

Manufacturer P/N

0624431

Part Number

6.491 031

Manufacturer

Trajan Scientific

Ext. Ø

0.363 mm

Tubing 2m x 530µm/680µm

Manufacturer P/N

0624479

Part Number

7.671 786

Manufacturer

Trajan Scientific

Ext. Ø

0.68 mm

Tubing 25m x 100µm/363µm

Manufacturer P/N

0624455

Part Number

7.671 389

Manufacturer

Trajan Scientific

Ext. Ø

0.363 mm

Tube 25M X 0,53mm/0,68mm VSD

Manufacturer P/N

064034

Part Number

7.631 796

Manufacturer

Trajan Scientific

Ext. Ø

0.68 mm

Methyl deactivated capillary 2VSD/025 0.025 i.d.

Manufacturer P/N

062442

Part Number

6.050 233

Manufacturer

Trajan Scientific

Ext. Ø

0.285 mm

Capillary 2m x 170µm/110µm

Manufacturer P/N

062446

Part Number

6.325 249

Manufacturer

Trajan Scientific

Ext. Ø

0.17 mm

Tubing 2m x 75µm/363µm

Manufacturer P/N

06244502

Part Number

7.671 383

Manufacturer

Trajan Scientific

Ext. Ø

0.363 mm

More items to explore

Capillary, phenyl deactivated fused silica

ProductMaterialLengthMfr#Part#AvailabilityPrice
Quartz glass5 m0641146.260 570$294.21

Frequently asked questions

It features a 430 µm outer diameter, 320 µm inner diameter, and a 2-meter length, ideal for accurate and low-interaction sample transport. Its deactivated inner surface minimizes analyte adsorption, making it suitable for sensitive chromatographic and analytical applications.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story