Representative Image

VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, Three Stage, Certification (NRTL): C/US, 100 to 115 V/50 to 60 Hz, 120 V/60 Hz, US Mains Cable

Max. voltage

Plug type

Power supply

Specifications

Compare models
HS Code #
84141089
Connection pressure side
DN 8-10 mm
Connection suction side
DN 8-10 mm
Depth
243 mm
Dimensions (WxDxH)
319 x 243 x 374 mm
Flow rate
3.4 m³/h
Power supply frequency
50/60 Hz
Height
374 mm
IP code
IP 40
Max. permitted ambient temp.
40 °C
Max. voltage
115 V

Alternative in-stock items

$12,740.38

Inc. GST

Available soon

Product description

The VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors. Its documented configuration includes electrical supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz, connection: US Mains Cable, and pump design: Three-Stage.

Key Features:

  • Brand: VACUUBRAND
  • Model: MD 4C NT
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 100-115 V, 120 V, 50-60 Hz, 60 Hz
  • Connection: US Mains Cable
  • Pump Design: Three-Stage
  • Certification: NRTL: C/US
  • Chemical and Vapour Resistance: Good chemical resistance and vapor tolerance
  • Vacuum Performance: High performance even at low vacuum
  • Gas Ballast Performance: Good vacuum even with gas ballast
  • Noise and Vibration: Quiet and ultra low vibration
  • Operation: Oilfree
  • Separators: Inlet and outlet separator
  • Applications: This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors
  • Inlet Separator: The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets
  • Outlet Separator: The separator at the outlet collects condensate and avoids condensate backflow towards the pump

The VACUUBRAND Chemistry Diaphragm Pump MD 4C NT +2AK, three-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081$145.25
PVC34.9 mm206860634.714 084$382.93
PVC38.1 mm206860654.714 085$445.18
PVC15.9 mm206860614.714 082$169.77
PVC22.3 mm206860624.714 083$224.48

Compare similar models

Chemistry diaphragm pump MD 4C NT +2AK, three stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US mains cable

Manufacturer P/N

20736603

Part Number

4.670 505

Manufacturer

VACUUBRAND​

Max. voltage

115 V

Chemical diaphragm pump MD 4C NT + 2AK three-tier certification (NRTL): C / US 230 V / 50-60 Hz, CEE power cable

Manufacturer P/N

20736600

Part Number

4.661 095

Manufacturer

VACUUBRAND​

Max. voltage

230 V

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stock$2,250.41
UKME 1C207211029.880 936$2,250.41
CHME 1C207211019.880 935$2,250.41
USME 1C207211039.880 937$2,250.41

Chemistry vacuum system MZ 2C NT AK/M/D

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUMZ 2C NT + AK + M + D207327006.231 821$7,737.79
USMZ 2C NT + AK + M + D207327034.670 448$7,737.79

Frequently asked questions

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story