Representative Image

VACUUBRAND VARIO Chemistry Pumping Unit, PC 3003 VARIO, Select, 100 to 120V / 50 to 60Hz, US Mains Cable

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
419 mm
Dimensions (WxDxH)
243 x 419 x 457 mm
Flow rate
46.67 l/min
Height
457 mm
Plug type
US
Type
PC 3003 VARIO ® select
Ultimate vacuum
0.6 mbar
Ultimate vacuum with gas ballast
1.5 mbar
UNSPSC
40151502
Weight
21.1 kg

$21,493.03

Inc. GST

Available soon

Product description

The VACUUBRAND VARIO Chemistry Pumping Unit, PC 3003 VARIO select, 100-120 V / 50-60 Hz, US Mains Cable is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. The combination of speed controlled VARIO ® chemistry diaphragm pumps and the new VACUU·SELECT vacuum controller makes the VARIO ® select chemistry pumps the ideal solution for chemical processes that require precise vacuum, such as rotary evaporation, vacuum drying or vacuum concentration. Its documented configuration includes electrical supply: 100-120 V, 50-60 Hz, connection: US Mains Cable, and chemical resistance: High chemical resistance and therefore ideally suited for pumping aggressive gases and vapours.

Key Features:

  • Brand: VACUUBRAND
  • Model: PC 3003 VARIO
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 100-120 V, 50-60 Hz
  • Connection: US Mains Cable
  • Chemical Resistance: High chemical resistance and therefore ideally suited for pumping aggressive gases and vapours
  • Pressure Control: Short process times and smooth running due to optimal setting of the pressure via the VACUU·SELECT controller
  • Vacuum Control: The VARIO ® technology controls the vacuum precisely and efficiently via motor speed
  • Efficiency and Noise: Power consumption, maintenance and noise are exceptionally low
  • Solvent Recovery: The outlet catchpot and solvent condenser combine to prevent solvent vapor emissions into the lab, allowing for nearly full recovery of solvents
  • Power Cord Options: Country-specific power cord versions available on request

The VACUUBRAND VARIO Chemistry Pumping Unit, PC 3003 VARIO select, 100-120 V / 50-60 Hz, US Mains Cable supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081$145.25
PVC34.9 mm206860634.714 084$382.93
PVC38.1 mm206860654.714 085$445.18
PVC15.9 mm206860614.714 082$169.77
PVC22.3 mm206860624.714 083$224.48

Compare similar models

VARIO chemistry pumping unit, PC 3003 VARIO select, 100-120V / 50-60Hz, US mains cable

Manufacturer P/N

20738453

Part Number

4.670 559

Manufacturer

VACUUBRAND​

Plug type

US

Chemistry pumping unit PC 3003 VARIO select 230 V / 50-60 Hz, CEE mains cable

Manufacturer P/N

20738450

Part Number

6.311 665

Manufacturer

VACUUBRAND​

Plug type

EU

Pump system PC 3003 VARIO select 230 V / 50-60 Hz, CH mains cable

Manufacturer P/N

20738451

Part Number

4.665 247

Manufacturer

VACUUBRAND​

Plug type

CH

VARIO chemistry pumping unit, PC 3003 VARIO select, 200-230V / 50-60Hz, UK mains cable

Manufacturer P/N

20738452

Part Number

4.670 558

Manufacturer

VACUUBRAND​

Plug type

UK

More items to explore

Chemistry pumping unit PC 101 NT

Frequently asked questions

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. The combination of speed controlled VARIO ® chemistry diaphragm pumps and the new VACUU·SELECT vacuum controller makes the VARIO ® select chemistry pumps the ideal solution for chemical processes that require precise vacuum, such as rotary evaporation, vacuum drying or vacuum concentration.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story