Bohlender b.safe Waste Cap S60 with Funnel 2x UNF1/4", 1x GL14, 1x NPT1/8"

Brand:Bohlender

Specifications

HS Code #
39235090
Capillary connections
2
Connection for exhaust filter
1
Hose connections
1
Material
PP
No. of blind plugs
1
No. of fittings
2 x 1,6/ 2,2/ 3,2 mm
No. of olives
1
Thread
S 60
UNSPSC
41115700

$662.68

Inc. GST

Available soon

Product description

The Bohlender b.safe Waste Cap S60 with Funnel is engineered for safe and efficient liquid disposal in laboratory settings. This screw cap features a freely movable PTFE insert and supports connecting capillaries with outer diameters of 1.6 mm, 2.2 mm, or 3.2 mm, as well as hose olives for tubing with inner diameters from 5.5 to 8 mm. It includes two UNF 1/4"" connections, one GL14 port (for optional exhaust air filter, not included), and one NPT 1/8"" hose connection, offering versatile compatibility for secure waste handling systems. Crafted from high-quality polypropylene (PP), the cap comes with a filling funnel that has an integrated automatic stopcock with a grip for hands-free operation and enhanced safety. The stopcock opens by pushing the grip and automatically closes when the grip is released; the grip position also indicates whether the stopcock is closed.

Key Features:

  • Brand: Bohlender
  • Thread: S60 with freely movable PTFE insert
  • Connections: 2x UNF 1/4"", 1x GL14, 1x NPT 1/8"" hose connection
  • Material: High-quality polypropylene (PP)
  • Includes: Filling funnel with automatic stopcock and grip, fittings, blind fitting, hose olive
  • Application: Ideal for solvent waste containers to enhance safety, prevent vapor release, and streamline waste collection

Scope of Supply:

  • Filling funnel (automatic stopcock with grip)
  • Fittings (UNF 1/4“)
  • Blind fitting (UNF 1/4“)
  • Hose olive (NPT 1/8")

Ideal for laboratories using solvent waste containers, this Bohlender waste cap enhances safety, prevents vapor release, and streamlines waste collection.

Downloads

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stock$217.94
PPMM 506-026.313 840In stock$295.90
PPLM 506-036.313 841In stock$379.18

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618$30.12
PTFE45 mmM 503-054.681 619$58.47
PP30 mmM 503-084.681 620$28.35
PP32 mmM 503-094.681 621$24.81
PP23 mmM 503-104.681 622$24.81
PP26 mmM 503-114.681 623$24.81
PP26 mmM 503-124.681 624$24.81
PP30 mmM 503-134.681 625$24.81
PP36 mmM 503-144.681 626$24.81
PTFE45 mmM 503-154.681 627$62.02
PP40 mmM 503-164.681 628$24.81
PP48 mmM 513-014.681 643$24.81
PP41 mmM 513-024.681 644$24.81
PP30 mmM 518-014.681 647$28.35

Compare similar models

b.safe Waste Cap S60 with Funnel 2x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 360-25

Part Number

4.681 598

Manufacturer

Bohlender

b.safe Waste Cap S60 with Funnel 2x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 360-35

Part Number

4.681 599

Manufacturer

Bohlender

Frequently asked questions

It is engineered for safe and efficient liquid disposal in laboratory settings. This screw cap features a freely movable PTFE insert and supports connecting capillaries with outer diameters of 1.6 mm, 2.2 mm, or 3.2 mm, as well as hose olives for tubing with inner diameters from 5.5 to 8 mm. It includes two UNF 1/4" connections, one GL14 port (for optional exhaust air filter, not included), and one NPT 1/8" hose connection, offering versatile compatibility for secure waste handling systems. Crafted from high-quality polypropylene (PP), the cap comes with a filling funnel that has an integrated automatic stopcock with a grip for hands-free operation and enhanced safety. The stopcock opens by pushing the grip and automatically closes when the grip is released; the grip position also indicates whether the stopcock is closed.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story