Representative Image

Heidolph Scientific Promax 1020 UK-Plug

Brand:Heidolph

Plug type

Specifications

Compare models
HS Code #
84798200
Depth
375 mm
Depth moving table
258 mm
Dimensions (WxDxH)
320 x 375 x 125 mm
Display
Digital
Power supply frequency
50/60 Hz
Height
125 mm
IP code
IP 30
Max. loading capacity
5 kg
Max. permitted ambient temp.
31 °C
Max. relative humidity rate
80 %

$4,297.28

Inc. GST

Available soon

Product description

The Heidolph Scientific Promax 1020 UK-plug is a laboratory shaker designed for laboratory use. Compact model for a medium sample throughput with an ideal motion for separatory funnels. This clearly specified configuration helps laboratories select the appropriate laboratory shaker for their workflow.

Key Features:

  • Brand: Heidolph Scientific
  • Product Type: Laboratory Shaker
  • Separatory Funnel Mixing: Compact design provides a motion suited to separatory funnels and medium sample throughput.
  • Timer: Timer can be set from 0 to 999 minutes.

The Heidolph Scientific Promax 1020 UK-plug is a practical choice for laboratories requiring a laboratory shaker. Its Compact model for a medium sample throughput with an ideal motion for separatory funnels and Timer from 0 to 999 min support straightforward day-to-day use.

Accessories

Accessories for shakers and mixers

ProductDescriptionForMfr#Part#AvailabilityPrice
Attachment for 10 test tubes 10 or 60mm ?Reax Top, Reax Control549-01000-009.730 045$123.96
Adapter for 20 test tubes dia. 10 to 18mmReax 2549-21000-009.730 222$824.60
Frame for tension roller only. Supplied without tension rollerUnimax 2010, Promax 2020, Polymax 2040549-50000-009.839 811$432.96
Tension roller and frame complete. Order at least 2Unimax 2010, Promax 2020, Polymax 2040549-58000-009.839 812$174.26
Universal perforated platform 2000Unimax 2010, Promax 2020, Polymax 2040549-59000-009.839 813$441.94
Attachment with 2 tension rollersVibramax 100, Rotamax 120549-81000-009.839 844$303.61
Test tube stand for up to 6 Eppendorf vessels (1.5ml)Reax Top, Reax Control549-04000-006.229 903$118.57
V2A support rod with vessel holderReax Top, Reax Control549-20000-009.730 021$255.11
Set of holders for four 0.5I bottlesReax 20/4, Reax 20/8, Reax 20/12549-27000-009.839 809$219.18
Universal perforated platform 1000Unimax 1010, Duomax 1030, Polymax 1040, Promax 1020549-59200-009.839 814$326.97
Spare tension rollerVibramax 100, Rotamax 12011-008-007-087.078 546$120.37
Tension plate for caps allows for the use of common bottles with dia. 94mmReax 20/4, Reax 20/8, Reax 20/1211-001-001-817.055 418$35.93
Attachment with 2 tension rollersUnimax 1010, Duomax 1030, Polymax 1040, Promax 1020549-70000-009.839 869$635.97
Universal adapter (for flasks, bottles, test tube racks, etc.)Reax 2549-30000-009.730 223$1,144.38
Spare tension rollerUnimax 1010, Duomax 1030, Polymax 1040, Promax 1020549-71000-009.839 870$172.47
Set of holders for four 1I bottlesReax 20/4, Reax 20/8, Reax 20/12549-26000-009.839 808$170.67
Multi-storey attachment. Includes perforated platform 2000 and 4 supporting rodsUnimax 2010, Promax 2020, Polymax 2040549-62000-009.839 826$786.88
Tray 100 with universal boringsVibramax 100, Rotamax 120549-59100-006.229 800$233.55

Compare similar models

Promax 1020 UK-plug
Available soon
Heidolph Scientific Promax 1020 UK-Plug

$4,297.28

Inc. GST

Manufacturer P/N

543-22332-06

Part Number

4.703 284

Manufacturer

Heidolph

Plug type

UK

Shakers,with rubber mat,useful area 290x258 mm PROMAX 1020,reciprocating motion frequency 30-500 1/min

Manufacturer P/N

543-22332-00

Part Number

9.839 853

Manufacturer

Heidolph

Plug type

EU

Promax 1020 CH-plug
Available soon
Heidolph Scientific Promax 1020 CH-Plug

$4,297.28

Inc. GST

Manufacturer P/N

543-22332-02

Part Number

4.703 283

Manufacturer

Heidolph

Plug type

CH

Frequently asked questions

Compact model for a medium sample throughput with an ideal motion for separatory funnels. It is intended for laboratory applications requiring a laboratory shaker.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story