Representative Image

Kern & Sohn Digital Power Measuring Unit FH 500 – Max. 500 N / 0.1 N for Pull and Pressure Measurements

Max. measured value

Measured range

Readability

Specifications

Compare models
HS Code #
90248000
Depth
36 mm
Dimensions (WxDxH)
66 x 36 x 230 mm
Display
Digital
Height
230 mm
Max. measured value
500 N
Measured range
500 N
Plug type
EU
Readability
0,1 N
Type of auxiliary energy
Rechargeable battery
UNSPSC
41111934

$1,077.21

Inc. GST

Available soon

Product description

The Kern & Sohn Digital Power Measuring Unit FH 500 is a high-precision force measurement device designed for accurate pull and pressure force measurements. With a maximum capacity of 500 N and an impressive resolution of 0.1 N, this digital power measuring unit is ideal for industrial and laboratory environments where precision and reliability are paramount. It provides accurate readings for testing, calibration, and quality assurance processes.

Key Features:

  • Brand: Kern & Sohn
  • Max. Load: 500 N
  • Resolution: 0.1 N
  • Application: Suitable for pull and pressure force measurements
  • Display: Digital display for easy and clear data reading; turnable with backlight
  • Internal Sensor: Digital force gauge with integrated measuring cell
  • Data Interface: RS-232 for data transfer
  • Units: Selectable measuring units: N, lb, kg
  • Measurement Modes: Peak-Hold function to capture peaks or Track function for continuous measurement (approx. 10 s)
  • Limit Settings: Programmable Max./Min. limits for pull and push with acoustic and optical signals for efficient testing
  • Auto Power-Off: Power-saving feature
  • Memory: Internal memory for up to 10 measurements
  • Statistics: Mini Statistics Kit calculates average, min., max., and count from stored results
  • Compatibility: Can be mounted on all SAUTER test stands
  • Precision: High-accuracy performance for testing and calibration applications

Scope of Supply:

  • Force gauge
  • Carrying case

The Kern & Sohn FH 500 is built to meet the needs of demanding force measurement tasks, offering durability and precision for industrial, laboratory, and scientific use.

Downloads

Compare similar models

Digital Power measuring unit FH 500 max. 500 N / 0.1 N, for pull- and pressure measurements

Manufacturer P/N

FH 500

Part Number

6.270 965

Manufacturer

KERN & SOHN

Max. measured value

500 N

Digital Power measuring unit FH20 max. 20 N / 0.01 N, for pull- and pressure measurements

Manufacturer P/N

FH 20

Part Number

6.270 961

Manufacturer

KERN & SOHN

Max. measured value

20 N

FH-S Digital power meter FH 5 max. 5 N / 0.001 N, for pull- and pressure measurements with RS 232

Manufacturer P/N

FH 5

Part Number

6.251 322

Manufacturer

KERN & SOHN

Max. measured value

5 N

Digital Power measuring unit FH 50 max. 50 N / 0.01 N, for pull- and pressure measurements

Manufacturer P/N

FH 50

Part Number

6.270 962

Manufacturer

KERN & SOHN

Max. measured value

50 N

Digital Power measuring unit FH 100 max. 100 N / 0.05 N, for pull- and pressure measurements

Manufacturer P/N

FH 100

Part Number

6.270 963

Manufacturer

KERN & SOHN

Max. measured value

100 N

Digital Power measuring unit FH 200 max. 200 N / 0.1 N, for pull- and pressure measurements

Manufacturer P/N

FH 200

Part Number

6.270 964

Manufacturer

KERN & SOHN

Max. measured value

200 N

More items to explore

Digital force gauge FH-S with screw-in tension clamp

ProductPlug typeType of auxiliary energyMfr#Part#AvailabilityPrice
EURechargeable batteryFH 500S714.691 172$1,294.89

Frequently asked questions

It is a high-precision force measurement device designed for accurate pull and pressure force measurements. With a maximum capacity of 500 N and an impressive resolution of 0.1 N, this digital power measuring unit is ideal for industrial and laboratory environments where precision and reliability are paramount. It provides accurate readings for testing, calibration, and quality assurance processes.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story