Representative Image

Ludwig Schneider Precision Density Hydrometer M50 1.050–1.100 g/cm³, 0.001 g/cm³ Division, 270 mm Length, without Thermometer

Max. measured value

Measured range

Min. measured value

Specifications

Compare models
HS Code #
90258080
Division
0.001 g/cm³
Length
270 mm
Max. measured value
1.100 g/cm³
Measured range
1.050 ... 1.100 g/cm³
Min. measured value
1.050 g/cm³
Reference temperature
20 °C
Standard
DIN 12791
UNSPSC
41113024

$102.77

Inc. GST

Available soon

Product description

The Ludwig Schneider Precision Density Hydrometer M50 is a high-precision instrument designed for accurate density measurements in laboratory settings. Covering a measurement range of 1.050 to 1.100 g/cm³ with a fine division of 0.001 g/cm³, this hydrometer ensures precise readings. Manufactured according to DIN 12791 standards, it is calibrated at a reference temperature of 20 °C. The 270 mm length facilitates easy handling, and the absence of an integrated Thermometer allows for flexible temperature measurement methods. Each unit is packed in a square plastic sleeve for protection during storage and transport.

Key Features:

  • Brand: Ludwig Schneider
  • Measurement Range: 1.050–1.100 g/cm³
  • Division: 0.001 g/cm³
  • Length: 270 mm
  • Reference Temperature: 20 °C
  • Standard: DIN 12791
  • Thermometer: Not included
  • Packaging: Square plastic sleeve

This hydrometer is ideal for laboratories requiring precise and reliable density measurements across various applications.

Compare similar models

Precision Density hydrometer M50 1.050-1.100:0.001g/cm³ length 270mm, w/o. thermometer

Manufacturer P/N

3172010

Part Number

6.273 155

Manufacturer

Ludwig Schneider

Max. measured value

1.100 g/cm³

Precision density hydrometer M50 1,950-2,000:0.001g/cm³, DIN 12791, length 190mm, w/o. thermometer

Manufacturer P/N

3172028

Part Number

6.287 277

Manufacturer

Ludwig Schneider

Max. measured value

2.000 g/cm³

Precision Density hydrometers Type M 50-130, measuring range 1.300 - 1350 in 0.001 gr / cm3, length 270 mm, without therm.

Manufacturer P/N

3172015

Part Number

6.273 746

Manufacturer

Ludwig Schneider

Max. measured value

1.350 g/cm³

Frequently asked questions

It is a high-precision instrument designed for accurate density measurements in laboratory settings. Covering a measurement range of 1.050 to 1.100 g/cm³ with a fine division of 0.001 g/cm³, this hydrometer ensures precise readings. Manufactured according to DIN 12791 standards, it is calibrated at a reference temperature of 20 °C. The 270 mm length facilitates easy handling, and the absence of an integrated Thermometer allows for flexible temperature measurement methods. Each unit is packed in a square plastic sleeve for protection during storage and transport.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story