Representative Image

Macherey-Nagel Chromabond Columns Easy BigPack, Volume 6 mL Content of Sorbent, 200 mg Material PP, with PE Filter Elements Packed in 5 Bags, with 50 pcs

Package

Package capacity

Specifications

Compare models
HS Code #
38221900
Base material
PS/DVB copolymer
Endcapped
No
Filter element material
PE
No. of packages
5
Package
5 x Bag of 50 pcs
Package capacity
50 pcs
Particle size
80 µm
Particle type
Fully porous
pH stability
1 ... 14

$2,640.10

Inc. GST

Available soon

Product description

The Macherey-Nagel Chromabond Columns Easy BigPack are designed for efficient solid-phase extraction (SPE) in laboratory applications. With a volume of 6 mL and a sorbent content of 200 mg per column, these columns offer excellent performance for sample purification and extraction. Made from high-quality PP material and featuring PE filter elements, these columns ensure reliable and reproducible results. The BigPack packaging contains 5 bags with 50 columns, providing a convenient and cost-effective solution for laboratories with high throughput needs.

Key Features:

  • Brand: Macherey-Nagel
  • Material: PP material with PE filter elements for durability and performance
  • Volume: 6 mL per column
  • Sorbent Content: 200 mg per column
  • Packaging: Packed in 5 bags with 50 columns for bulk usage
  • Application: Ideal for solid-phase extraction (SPE) in laboratory settings

Macherey-Nagel Chromabond Columns provide an efficient and reliable solution for high-throughput sample extraction and purification in analytical laboratories.

Downloads

Compare similar models

CHROMABOND columns EASY BIGpack volume: 6 ml, content of sorbent: 200 mg material: PP, with PE-filterelements packed in 5 bags with 50 pcs.

Manufacturer P/N

730755.250

Part Number

4.003 724

Manufacturer

Macherey-Nagel

No. of packages

5

CHROMABOND columns EASY volume: 3 ml, content of sorbent: 500 mg material: PP, pack of 30

Manufacturer P/N

730759

Part Number

4.003 728

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns EASY BIGpack volume: 3 ml, content of sorbent: 200 mg material: PP, with PE-filterelements packed in 5 bags with 50 pcs.

Manufacturer P/N

730754.250

Part Number

4.003 723

Manufacturer

Macherey-Nagel

No. of packages

5

CHROMABOND columns EASY volume: 6 ml, content of sorbent: 500 mg, PP, pack of 30

Manufacturer P/N

730756

Part Number

6.224 850

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns EASY volume: 15 ml, content of sorbent: 500 mg material: PP, pack of 20

Manufacturer P/N

730757

Part Number

4.003 726

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns EASY volume: 1 ml, content of sorbent: 30 mg material: PP, pack of 30

Manufacturer P/N

730751

Part Number

4.003 719

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns EASY volume: 3 ml, content of sorbent: 60 mg material: PP, pack of 30

Manufacturer P/N

730753

Part Number

4.003 721

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns EASY volume: 6 ml, content of sorbent: 200 mg material: PP, pack of 30

Manufacturer P/N

730755

Part Number

6.234 375

Manufacturer

Macherey-Nagel

No. of packages

-

CHROMABOND columns EASY volume: 3 ml, content of sorbent: 200 mg material: PP, pack of 30

Manufacturer P/N

730754

Part Number

6.226 452

Manufacturer

Macherey-Nagel

No. of packages

-

Frequently asked questions

It are designed for efficient solid-phase extraction (SPE) in laboratory applications. With a volume of 6 mL and a sorbent content of 200 mg per column, these columns offer excellent performance for sample purification and extraction. Made from high-quality PP material and featuring PE filter elements, these columns ensure reliable and reproducible results. The BigPack packaging contains 5 bags with 50 columns, providing a convenient and cost-effective solution for laboratories with high throughput needs.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story