Macherey-Nagel OPTIMA 624 Capillary Column, ID 0.32 mm, Film Thickness 1.8 µm, Length 60 m

Film thickness

Int. Ø

Length

Specifications

Compare models
Film thickness
1.8 µm
Int. Ø
0.32 mm
Length
60 m
Material column
Quartz glass
Max. temperature programme
300 °C
Polarity
Mid-polar
Temperature max. isotherm
280 °C
UNSPSC
41115710
USP listing
G43

$2,663.14

Inc. GST

Available soon

Product description

The Macherey-Nagel OPTIMA 624 Capillary Column, ID 0.32 mm, Film Thickness 1.8 µm, Length 60 m is designed for gas chromatography applications requiring a medium polar phase. Recommended for environmental analyses, this column uses a 6% cyanopropyl-phenyl and 94% dimethylpolysiloxane phase for compatible analytical workflows.

Key Features:

  • Brand: Macherey-Nagel
  • Product Type: Capillary column
  • Range: OPTIMA 624
  • Inner Diameter: 0.32 mm
  • Film Thickness: 1.8 µm
  • Length: 60 m
  • Phase: 6% cyanopropyl-phenyl and 94% dimethylpolysiloxane
  • USP Phase: G43
  • Phase Type: Medium polar phase
  • Application: Recommended for environmental analyses
  • Maximum Temperature: 280 °C for isothermal operation and 300 °C for short isotherms in a temperature programme

This Macherey-Nagel OPTIMA 624 capillary column is suitable for users requiring a 60 m medium polar GC column with 0.32 mm ID and 1.8 µm film thickness for environmental analysis workflows.

Downloads

Compare similar models

Capillary column OPTIMA 624 ID: 0.32 mm, film thickness: 1.8 µm Length: 60 m

Manufacturer P/N

726787.60

Part Number

4.003 219

Manufacturer

Macherey-Nagel

Film thickness

1.8 µm

Capillary column OPTIMA 624 ID: 0.32 mm, film thickness: 1.8 µm Lenght: 30 m

Manufacturer P/N

726787.30

Part Number

4.003 217

Manufacturer

Macherey-Nagel

Film thickness

1.8 µm

Capillary column OPTIMA-624 ID: 0.53 mm, film thickness: 3 µm Length: 30 m

Manufacturer P/N

726789.30

Part Number

4.003 221

Manufacturer

Macherey-Nagel

Film thickness

3.0 µm

Capillary column OPTIMA 624 ID: 0.25 mm, film thickness: 1,4 µm Length: 60 m

Manufacturer P/N

726785.60

Part Number

4.003 213

Manufacturer

Macherey-Nagel

Film thickness

1.4 µm

Capillary column OPTIMA 624 ID: 0.25 mm, film thickness: 1.4 µm Length: 30 m

Manufacturer P/N

726785.30

Part Number

4.003 211

Manufacturer

Macherey-Nagel

Film thickness

1.4 µm

Capillary column OPTIMA-624 ID: 0.53 mm, film thickness: 3 µm length: 25 m

Manufacturer P/N

726789.25

Part Number

4.003 220

Manufacturer

Macherey-Nagel

Film thickness

3.0 µm

Capillary column OPTIMA 624 ID: 0.32 mm, film thickness: 1.8 µm Length: 50 m

Manufacturer P/N

726787.50

Part Number

4.003 218

Manufacturer

Macherey-Nagel

Film thickness

1.8 µm

Capillary column OPTIMA-624 ID: 0.25 mm, film thickness: 1,4 µm length: 50 m

Manufacturer P/N

726785.50

Part Number

4.003 212

Manufacturer

Macherey-Nagel

Film thickness

1.4 µm

Frequently asked questions

It is designed for gas chromatography applications requiring a medium polar phase. Recommended for environmental analyses, this column uses a 6% cyanopropyl-phenyl and 94% dimethylpolysiloxane phase for compatible analytical workflows.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story

$2,663.14

Inc. GST