Macherey-Nagel Solid Phase Extraction Cartridges Chromafix PS-RP-S, Average Content of Sorbent 200mg, Pack of 50

Type

Specifications

Compare models
Base material
PS/DVB copolymer
Endcapped
No
Filter element material
PE
Package
50 pcs
Package capacity
50 pcs
Particle size
100 µm
Particle type
Fully porous
pH stability
1 ... 14
Type
PS-RP

$538.65

Inc. GST

Available soon

Product description

The Macherey-Nagel Solid Phase Extraction Cartridges Chromafix PS-RP-S are designed for efficient solid-phase extraction of a variety of analytes in different laboratory applications. With an average sorbent content of 200mg, these cartridges provide reliable retention and recovery for polar and non-polar compounds. Constructed from high-quality materials, these cartridges ensure consistent performance and high throughput. Each pack contains 50 cartridges, making them an excellent choice for laboratories requiring large volumes of sample processing.

Key Features:

  • Brand: Macherey-Nagel
  • Sorbent Content: 200mg per cartridge
  • Material: High-quality materials for consistent performance
  • Packaging: Pack of 50 cartridges
  • Application: Efficient solid-phase extraction for a wide range of analytes

Macherey-Nagel Chromafix PS-RP-S cartridges offer an ideal solution for laboratories needing high-efficiency sample extraction with consistent, reproducible results.

Compare similar models

Solid Phase Extraction Cartridges CHROMAFIX PS-RP (S) average content of sorbent: 200 mg pack of 50

Manufacturer P/N

731877

Part Number

4.003 869

Manufacturer

Macherey-Nagel

Type

PS-RP

Solid Phase Extraction Cartridges CHROMAFIX PS-OH- (S) average content of sorbent: 200 mg pack of 50

Manufacturer P/N

731868

Part Number

4.003 867

Manufacturer

Macherey-Nagel

Type

PS-OH-

CHROMAFIX Clean-up cartridges for IC CHROMAFIX PS-Ag+ (S) average content of sorbent: 240 mg pack of 50 , no dan. goods

Manufacturer P/N

731866

Part Number

4.003 865

Manufacturer

Macherey-Nagel

Type

PS-Ag+

CHROMAFIX Clean-up cartridges for IC CHROMAFIX PS-OH- (M) average content of sorbent: 380 mg pack of 50

Manufacturer P/N

731860

Part Number

4.003 861

Manufacturer

Macherey-Nagel

Type

PS-OH-

Solid Phase Extraction Cartridges CHROMAFIX PS-H+ (S) average content of sorbent: 230 mg pack of 50

Manufacturer P/N

731867

Part Number

4.003 866

Manufacturer

Macherey-Nagel

Type

PS-H+

Solid Phase Extraction Cartridges CHROMAFIX PS-Ba2+ (S) average content of sorbent: 280 mg pack of 50

Manufacturer P/N

731871

Part Number

4.003 868

Manufacturer

Macherey-Nagel

Type

PS-Ba2+

Clean-up catridges CHROMAFIX PS-H+ (M) average content of sorbent: 430 mg pack of 50

Manufacturer P/N

731861

Part Number

7.401 474

Manufacturer

Macherey-Nagel

Type

PS-H+

Solid Phase Extraction Cartridges CHROMAFIX PS-OH- (L) average content of sorbent: 800 mg pack of 50

Manufacturer P/N

731862

Part Number

4.003 862

Manufacturer

Macherey-Nagel

Type

PS-OH

Clean-up cartridges CHROMAFIX PS-RP (M) average content of sorbent: 320 mg pack of 50

Manufacturer P/N

731875

Part Number

6.228 258

Manufacturer

Macherey-Nagel

Type

PS-RP

CHROMAFIX Clean-up cartridges for IC CHROMAFIX PS-AG+ (M) average content of sorbent: 480 mg pack of 50

Manufacturer P/N

731865

Part Number

4.003 864

Manufacturer

Macherey-Nagel

Type

PS-Ag+

Solid Phase Extraction Cartridges CHROMAFIX PS-H+ (L) average content of sorbent: 900 mg pack of 50

Manufacturer P/N

731863

Part Number

4.003 863

Manufacturer

Macherey-Nagel

Type

PS-H+

Clean-up cartridges CHROMAFIX PS-Ba 2+ (M) average content of sorbent: 550 mg pack of 50

Manufacturer P/N

731870

Part Number

7.402 218

Manufacturer

Macherey-Nagel

Type

PS-Ba2+

Frequently asked questions

It are designed for efficient solid-phase extraction of a variety of analytes in different laboratory applications. With an average sorbent content of 200mg, these cartridges provide reliable retention and recovery for polar and non-polar compounds. Constructed from high-quality materials, these cartridges ensure consistent performance and high throughput. Each pack contains 50 cartridges, making them an excellent choice for laboratories requiring large volumes of sample processing.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

1 min read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

1 min read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

1 min read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story

$538.65

Inc. GST