Representative Image

SI Analytics Standard Buffer Solutions, pH 9.18, L 4799, 60 Ampoules

pH value (25°C)

Specifications

Compare models
No. of packages
60
Package capacity
17 ml
pH value (25°C)
9.18
Container type
Ampoule
Content
60 x Ampoule of 17 ml
UNSPSC
41116166

$577.63

Inc. GST

Available soon

Product description

The SI Analytics Standard Buffer Solutions, pH 9.18, L 4799, 60 Ampoules, are designed for accurate calibration of pH measurement systems in laboratory and analytical environments. Manufactured in accordance with DIN 19266 standards, these buffer solutions provide consistent and reliable calibration in the alkaline range. Supplied in double-end ampoules, each portion is protected from contamination, ensuring high measurement accuracy and repeatability.

Key Features:

  • Brand: SI Analytics
  • DIN 19266 compliant calibration solution: Produced according to recognised standards, ensuring dependable and standardised pH calibration performance.
  • pH 9.18 buffer solution: Ideal for calibrating pH meters in the alkaline range, supporting accurate measurements across a wide range of applications.
  • Double-end ampoule design: Provides excellent protection against contamination, ensuring the solution remains pure until use and supporting reliable calibration results.
  • Hot steam sterilised: Enhances solution stability and shelf life, making it suitable for long-term storage and consistent laboratory use.
  • Preservative-free formulation: Eliminates the risk of interference from added chemicals, supporting accurate and reproducible calibration.
  • Supplied with manufacturer certificate: Provides traceability and quality assurance for laboratory and regulated environments.
  • Convenient ampoule format: Each 20 mL ampoule contains approximately 17 mL of solution, allowing controlled single-use application.
  • Pack of 60 ampoules: Suitable for laboratories with frequent calibration requirements and high-throughput workflows.

The SI Analytics Standard Buffer Solutions, pH 9.18, are a reliable choice for laboratories requiring accurate, contamination-protected, and traceable calibration standards. When you source through LabFriend, you gain access to trusted laboratory consumables, dependable supply, and support in selecting the right calibration products for your workflow. Choose LabFriend for pH buffer solutions that help maintain measurement accuracy, consistency, and operational efficiency.

Compare similar models

Standard buffer solutions pH 9.18, L 4799 60 ampoules

Manufacturer P/N

285138262

Part Number

7.022 799

Manufacturer

SI Analytics

pH value (25°C)

9.18

Standard buffer solutions L 4791 60 ampoules

Manufacturer P/N

285137977

Part Number

7.022 771

Manufacturer

SI Analytics

pH value (25°C)

1.68

Standard buffer solutions pH 4.01, L 4794 60 ampoules

Manufacturer P/N

285138246

Part Number

9.774 342

Manufacturer

SI Analytics

pH value (25°C)

4.01

Standard buffer solutions pH 6.87, L 4796 60 ampoules

Manufacturer P/N

285138254

Part Number

9.774 344

Manufacturer

SI Analytics

pH value (25°C)

6.87

Frequently asked questions

It are designed for accurate calibration of pH measurement systems in laboratory and analytical environments. Manufactured in accordance with DIN 19266 standards, these buffer solutions provide consistent and reliable calibration in the alkaline range. Supplied in double-end ampoules, each portion is protected from contamination, ensuring high measurement accuracy and repeatability.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story

$577.63