Representative Image

Thermo Finnpipette F1, 8-Channel Variable Volume 1-10µl

Accuracy

Capacity

Colour coding

Division

For tips

No. of channels

Precision

Specifications

Compare models
HS Code #
84798997
Accuracy
12,0 ± R%
Capacity
1 ... 10 µl
Colour coding
Pink
Division
0.02 µl
For tips
Finntip 10, Filter 10, Flex 10, Flex Filter 10
No. of channels
8
Precision
8,0 ≤·VK%
UNSPSC
41121504

$1,874.65

Inc. GST

Available soon

Product description

The Thermo Finnpipette F1, 8-channel variable volume 1-10µl, is engineered for efficient and precise liquid handling in high-throughput laboratory applications. With a variable volume range of 1µl to 10µl per channel, this pipette allows for simultaneous processing of multiple samples, enhancing productivity without compromising accuracy. Ideal for applications requiring parallel pipetting, the Finnpipette F1 ensures reliable performance, especially when used with Thermo Finn Finntip pipette tips.

Key Features:

  • Brand: Thermo Scientific
  • Volume Range: Variable volume from 1µl to 10µl per channel for flexible sample handling
  • Number of Channels: 8 channels for simultaneous pipetting, increasing throughput
  • Compatibility: Designed to work seamlessly with Thermo Finn Finntip pipette tips
  • Application: Ideal for high-throughput liquid handling in research and analytical procedures
  • Ergonomics: Lightweight design with adjustable finger rest to reduce user fatigue

The Thermo Finnpipette F1 multichannel pipette is an essential tool for laboratories that require efficient, accurate, and simultaneous handling of multiple samples, ensuring consistent results in high-throughput settings.

Downloads

Accessories

Pipette stand for single and multichannel microliter pipettes F1 / F2

ProductColourFor multi-channel pipettesMfr#Part#AvailabilityPrice
WhiteYes94204009.282 440$251.61

Pipette stand for Multichannel microliter pipettes

ProductFor multi-channel pipettesNo. of pipettesMfr#Part#AvailabilityPrice
Yes194203909.282 441$77.96

Compare similar models

Finnpipette F1, 8-channel variable volume 1-10µl

Manufacturer P/N

4661000N

Part Number

4.658 814

Manufacturer

Thermo Scientific

Accuracy

12,0 ± R%

Finnpipette F1, 8-channel variable volume 10-100µl

Manufacturer P/N

4661020N

Part Number

4.658 816

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 12-channel variable volume 1-10µl

Manufacturer P/N

4661040N

Part Number

4.658 818

Manufacturer

Thermo Scientific

Accuracy

12,0 ± R%

Finnpipette F1, 8-channel variable volume 5-50µl

Manufacturer P/N

4661010N

Part Number

4.658 815

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 8-channel variable volume 30-300µl

Manufacturer P/N

4661030N

Part Number

4.658 817

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 12-channel variable volume 10-100µl

Manufacturer P/N

4661060N

Part Number

4.658 820

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 12-channel variable volume 5-50µl

Manufacturer P/N

4661050N

Part Number

4.658 819

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 16-channel variable volume 5-50µl

Manufacturer P/N

4661090N

Part Number

4.658 823

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 12-channel variable volume 30-300µl

Manufacturer P/N

4661070N

Part Number

4.658 821

Manufacturer

Thermo Scientific

Accuracy

5,0 ± R%

Finnpipette F1, 16-channel variable volume 1-10µl

Manufacturer P/N

4661080N

Part Number

4.658 822

Manufacturer

Thermo Scientific

Accuracy

12,0 ± R%

Frequently asked questions

It is engineered for efficient and precise liquid handling in high-throughput laboratory applications. With a variable volume range of 1µl to 10µl per channel, this pipette allows for simultaneous processing of multiple samples, enhancing productivity without compromising accuracy. Ideal for applications requiring parallel pipetting, the Finnpipette F1 ensures reliable performance, especially when used with Thermo Finn Finntip pipette tips.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story