Representative Image

Thermo Finnpipette F2, 1-Channel Fixed Volume 10000µl, for FinnTips 10mL

Accuracy

Capacity

For tips

Precision

Specifications

Compare models
HS Code #
84798997
Accuracy
0,3 ± R%
Capacity
10000 µl
For tips
Finntip 10 ml, Filter 10 ml, Flex 10 ml Ext
No. of channels
1
Precision
0,2 ≤·VK%
UNSPSC
41121504

$402.22

Inc. GST

Available soon

Product description

The Thermo Finnpipette F2, 1-channel fixed volume pipette, is designed for precise liquid handling with a fixed volume of 10,000µl (10mL). Ideal for applications requiring consistent and accurate high-volume dispensing, this pipette ensures reliable sample transfers, enhancing laboratory productivity. Its ergonomic design, featuring a supportive finger rest, allows the hand to relax between pipetting cycles, reducing the risk of repetitive strain injury (RSI). Constructed with durable PVDF components, the Finnpipette F2 withstands harsh chemicals and UV light exposure, ensuring longevity in demanding laboratory environments. It is fully autoclavable without disassembly, simplifying decontamination processes. The Finnpipette F2 is compatible with FinnTips 10mL and Filter 10mL pipette tips, ensuring optimal performance and accuracy.

Key Features:

  • Brand: Thermo Scientific
  • Volume: Fixed volume of 10,000µl (10mL) for consistent liquid handling
  • Number of Channels: 1-channel design for precise sample processing
  • Compatibility: Designed for use with FinnTips 10mL and Filter 10mL pipette tips
  • Ergonomics: Lightweight handle with supportive finger rest to reduce RSI risk
  • Durability: Constructed with tough PVDF components that stand up to harsh chemicals and UV light exposure
  • Autoclavable: Fully autoclavable without disassembly, simplifying decontamination
  • Maintenance: Easy daily maintenance with detachable tip cone
  • Performance: Super Blow-out feature ensures efficient delivery of micro-volumes and prevents capillary action
  • Warranty: Backed by a 5-year warranty upon online registration

The Thermo Finnpipette F2 is an essential tool for laboratories requiring precise and reliable high-volume liquid handling, enhancing productivity and user comfort.

Downloads

Accessories

Pipette stand for single and multichannel microliter pipettes F1 / F2

ProductColourFor multi-channel pipettesMfr#Part#AvailabilityPrice
WhiteYes94204009.282 440$251.61

Compare similar models

Finnpipette F2, 1-channel fixed volume 10000µl, for Finntips 10ml

Manufacturer P/N

4652120

Part Number

9.282 462

Manufacturer

Thermo Scientific

Accuracy

0,3 ± R%

Finnpipette F2, 1-channel fixed volume 10µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4652020

Part Number

9.282 452

Manufacturer

Thermo Scientific

Accuracy

0,9 ± R%

Finnpipette F2, 1-channel fixed volume 1000µl, for Finntips Flex 1000,1000,1000 Ext.

Manufacturer P/N

4652080

Part Number

9.282 458

Manufacturer

Thermo Scientific

Accuracy

0,3 ± R%

Finnpipette F2, 1-channel fixed volume 200µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4652140

Part Number

9.282 464

Manufacturer

Thermo Scientific

Accuracy

0,4 ± R%

Finnpipette F2, 1-channel fixed volume 1µl, for Finntips Flex 10,10,50 Mikro

Manufacturer P/N

4652000

Part Number

9.282 450

Manufacturer

Thermo Scientific

Accuracy

4,0 ± R%

Finnpipette F2, 1-channel fixed volume 5µl, for Finntips Flex 10,10,50 Mikro

Manufacturer P/N

4652010

Part Number

9.282 451

Manufacturer

Thermo Scientific

Accuracy

1,4 ± R%

Finnpipette F2, 1-channel fixed volume 500µl, for Finntips Flex 1000,1000,1000 Ext.

Manufacturer P/N

4652070

Part Number

9.282 457

Manufacturer

Thermo Scientific

Accuracy

0,3 ± R%

Finnpipette F2, 1-channel fixed volume 50µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4652040

Part Number

9.282 454

Manufacturer

Thermo Scientific

Accuracy

0,6 ± R%

Finnpipette F2, 1-channel fixed volume 25µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4652030

Part Number

9.282 453

Manufacturer

Thermo Scientific

Accuracy

0,6 ± R%

Finnpipette F2, 1-channel fixed volume 20µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4652130

Part Number

9.282 463

Manufacturer

Thermo Scientific

Accuracy

0,6 ± R%

Finnpipette F2, 1-channel fixed volume 100µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4652050

Part Number

9.282 455

Manufacturer

Thermo Scientific

Accuracy

0,4 ± R%

Finnpipette F2, 1-channel fixed volume 5000µl, for Finntips 5ml

Manufacturer P/N

4652110

Part Number

9.282 461

Manufacturer

Thermo Scientific

Accuracy

0,3 ± R%

Finnpipette F2, 1-channel fixed volume 2000µl, for Finntips 5ml

Manufacturer P/N

4652090

Part Number

9.282 459

Manufacturer

Thermo Scientific

Accuracy

0,3 ± R%

Finnpipette F2, 1-channel fixed volume 250µl, for Finntips Flex 1000,1000,1000 Ext.

Manufacturer P/N

4652060

Part Number

9.282 456

Manufacturer

Thermo Scientific

Accuracy

0,4 ± R%

Finnpipette F2, 1-channel fixed volume 3000µl, for Finntips 5ml

Manufacturer P/N

4652100

Part Number

9.282 460

Manufacturer

Thermo Scientific

Accuracy

0,3 ± R%

Frequently asked questions

It is designed for precise liquid handling with a fixed volume of 10,000µl (10mL). Ideal for applications requiring consistent and accurate high-volume dispensing, this pipette ensures reliable sample transfers, enhancing laboratory productivity. Its ergonomic design, featuring a supportive finger rest, allows the hand to relax between pipetting cycles, reducing the risk of repetitive strain injury (RSI). Constructed with durable PVDF components, the Finnpipette F2 withstands harsh chemicals and UV light exposure, ensuring longevity in demanding laboratory environments. It is fully autoclavable without disassembly, simplifying decontamination processes. The Finnpipette F2 is compatible with FinnTips 10mL and Filter 10mL pipette tips, ensuring optimal performance and accuracy.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story