Thermo Finnpipette F2, 16-Channel Variable Volume 1-10 µl, For Finntips Flex 10 (384), 50 Mikro

Accuracy

Capacity

Colour coding

Division

For tips

No. of channels

Precision

Specifications

Compare models
HS Code #
84798997
Accuracy
0,24 ± R%
Capacity
1 ... 10 µl
Colour coding
Violet
Division
0.02 µl
For tips
Finntip 20, Filter 20
No. of channels
16
Precision
8,0 ≤·VK%
UNSPSC
41121504

$2,273.32

Inc. GST

Available soon

Product description

The Thermo Finnpipette™ F2 multichannel pipettes are available in 8-, 12- and 16-channel models with a selection of volume ranges. As with the single channel Finnpipette™ F2 pipettes, the AVG mechanism ensures a high level of accuracy and precision. In addition, in the low volume models the super blow-out function ensures accurate dispensing for even the lowest volumes.

Key Features:

  • Brand: Thermo
  • Model: Finnpipette F2
  • Channels: 16-channel for high-throughput liquid handling
  • Volume Range: Variable 1-10 µl
  • Compatibility: For Finntips Flex 10 (384)
  • Packaging: 50 Mikro
  • Mechanism: AVG mechanism for high accuracy and precision
  • Application: Ideal for precise multichannel liquid dispensing in laboratory settings

The Thermo Finnpipette F2 16-channel pipette is an essential tool for laboratories requiring accurate and efficient multichannel liquid handling across a wide range of volumes.

Downloads

Accessories

Pipette stand for single and multichannel microliter pipettes F1 / F2

ProductColourFor multi-channel pipettesMfr#Part#AvailabilityPrice
WhiteYes94204009.282 440$251.61

Pipette stand for Multichannel microliter pipettes

ProductFor multi-channel pipettesNo. of pipettesMfr#Part#AvailabilityPrice
Yes194203909.282 441$77.96

Compare similar models

Finnpipette F2, 16-channel variable volume 1-10 µl, for Finntips Flex 10 (384), 50 Mikro

Manufacturer P/N

4662080

Part Number

9.282 478

Manufacturer

Thermo Scientific

Accuracy

0,24 ± R%

Finnpipette F2, 8-channel variable volume 5-50 µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4662010

Part Number

9.282 471

Manufacturer

Thermo Scientific

Accuracy

0,75 ± R%

Finnpipette F2, 8-channel variable volume 10-100 µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4662020

Part Number

9.282 472

Manufacturer

Thermo Scientific

Accuracy

1,3 ± R%

Finnpipette F2, 8-channel variable volume 30-300 µl, for Finntips Flex 300,300

Manufacturer P/N

4662030

Part Number

9.282 473

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Finnpipette F2, 12-channel variable volume 30-300 µl, for Finntips Flex 300,300

Manufacturer P/N

4662070

Part Number

9.282 477

Manufacturer

Thermo Scientific

Accuracy

3,0 ± R%

Finnpipette F2, 8-channel variable volume 1-10 µl, for Finntips Flex 10,10,50 Mikro

Manufacturer P/N

4662000

Part Number

9.282 470

Manufacturer

Thermo Scientific

Accuracy

0,24 ± R%

Finnpipette F2, 12-channel variable volume 1-10 µl, for Finntips Flex 10,10,50 Mikro

Manufacturer P/N

4662040

Part Number

9.282 474

Manufacturer

Thermo Scientific

Accuracy

0,24 ± R%

Finnpipette F2, 16-channel variable volume 5-50 µl, for Finntips 50 Mikro

Manufacturer P/N

4662090

Part Number

9.282 479

Manufacturer

Thermo Scientific

Accuracy

0,75 ± R%

Finnpipette F2, 12-channel variable volume 5-50 µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4662050

Part Number

9.282 475

Manufacturer

Thermo Scientific

Accuracy

0,75 ± R%

Finnpipette F2, 12-channel variable volume 10-100 µl, for Finntips Flex 200,250 Univ.,200 Ext.

Manufacturer P/N

4662060

Part Number

9.282 476

Manufacturer

Thermo Scientific

Accuracy

1,3 ± R%

Frequently asked questions

It are available in 8, 12 and 16-channel models with a selection of volume ranges. As with the single channel Finnpipette™ F2 pipettes, the AVG mechanism ensures a high level of accuracy and precision. In addition, in the low volume models the super blow-out function ensures accurate dispensing for even the lowest volumes.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story