Representative Image

Vacuubrand Chemistry Membrane Pump MD 12C NT +AK+EK, Three-Stage, 230 V / 50–60 Hz, with CEE Mains Cable

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
616 mm
Dimensions (WxDxH)
387 x 616 x 395 mm
Flow rate
12 m³/h
Height
395 mm
Plug type
EU
Type
MD 12C NT + AK + EK
Ultimate vacuum
2 mbar
Ultimate vacuum with gas ballast
4 mbar
UNSPSC
40151502
Width
387 mm

Alternative in-stock items

$23,888.10

Inc. GST

Available soon

Product description

The Vacuubrand MD 12C NT +AK+EK is a high-performance, three-stage diaphragm pump designed for continuous, oil-free evacuation and pumping of corrosive gases and vapors in laboratory settings. Operating at 230 V with a frequency of 50–60 Hz, this pump comes equipped with a CEE mains cable for convenient integration into your laboratory infrastructure.

Key Features:

  • Brand: Vacuubrand
  • Type: Three-stage diaphragm pump for high-performance vacuum generation
  • Voltage: 230 V
  • Frequency: 50–60 Hz
  • Plug Type: CEE mains cable for easy connection
  • Ultimate Vacuum: 2 mbar (1.5 torr)
  • Ultimate Vacuum with Gas Ballast: 4 mbar (3 torr)
  • Max. Pumping Speed at 50 Hz: 12 m³/h
  • Max. Pumping Speed at 60 Hz: 7.0 cfm
  • Number of Heads: 8
  • Number of Stages: 3
  • Inlet Connection: Small flange KF DN 25 / hose nozzle DN 15 mm
  • Outlet Connection: Hose nozzle DN 15 mm
  • Rated Motor Power: 0.44 kW
  • Rated Motor Speed at 50/60 Hz: 1500/1800 min⁻¹
  • Protection Class (IEC 60529): IP 40
  • Dimensions (L x W x H): 533 mm x 260 mm x 359 mm
  • Weight: 28.1 kg
  • Noise Level: 52 dBA
  • ATEX Conformity: II 3G IIC T3 X (Internal Atm. only)

Note: An End User Declaration form must be completed after placing the order for this item.

This diaphragm pump is an essential tool for laboratories that require a dependable, efficient vacuum pump for a wide range of chemical and sample processing applications. Its robust construction and high chemical resistance make it suitable for demanding environments.

Downloads

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081$144.16
PVC34.9 mm206860634.714 084$380.07
PVC38.1 mm206860654.714 085$441.85
PVC15.9 mm206860614.714 082$168.50
PVC22.3 mm206860624.714 083$222.80

Compare similar models

Chemistry membrane pump MD 12C NT +AK+EK three-step, 230 V, 50-60 Hz CEE mains cable  2B350i

Manufacturer P/N

20743600

Part Number

9.880 968

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry membrane pump MD 12C NT +AK+EK three step, 230 V, 50-60 Hz with UK plug   2B350i

Manufacturer P/N

20743602

Part Number

9.880 970

Manufacturer

VACUUBRAND​

Plug type

UK

Chemistry membrane pump MD 12C NT +AK+EK three-step, 230 V, 50-60 Hz with Swiss plug   2B350i

Manufacturer P/N

20743601

Part Number

9.880 969

Manufacturer

VACUUBRAND​

Plug type

CH

Chemical vacuum system MD 12C NT +AK+EK 100-115 V/50-60 Hz, US plug 2B350i

Manufacturer P/N

20743603

Part Number

4.701 126

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stock$2,233.60
UKME 1C207211029.880 936$2,233.60
CHME 1C207211019.880 935$2,233.60
USME 1C207211039.880 937$2,233.60

Chemistry vacuum system MD 12C NT EK

ProductPlug typeTypeMfr#Part#AvailabilityPrice
UKMD 12C NT + EK207435029.880 967$22,787.22
EUMD 12C NT + EK207435009.880 965$22,787.22
CHMD 12C NT + EK207435019.880 966$22,787.22
USMD 12C NT + EK207435034.701 125$22,787.22

Frequently asked questions

It is a high-performance, three-stage diaphragm pump designed for continuous, oil-free evacuation and pumping of corrosive gases and vapors in laboratory settings. Operating at 230 V with a frequency of 50–60 Hz, this pump comes equipped with a CEE mains cable for convenient integration into your laboratory infrastructure.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story