Representative Image

KNF SIMDOS 10 Diaphragm Dosing Pump U FEM 1.10 KT.18S2 US-Plug - 115V/60HZ

Brand:KNF

Power supply frequency

Material head

Max. voltage

Plug type

Power supply

Type

Specifications

Compare models
HS Code #
84135040
Depth
150 mm
Dimensions (WxDxH)
93 x 150 x 144 mm
Dosing volume
1 ... 999 ml
Flow rate
1 ... 100 ml/min
Power supply frequency
60 Hz
Height
144 mm
IP code
IP 65
Liquid temperature
5 ... 80 °C
Material head
PP
Max. dosing volume
999 ml

$4,462.56

Inc. GST

Available soon

Product description

The KNF SIMDOS 10 Diaphragm Dosing Pump U FEM 1.10 KT.18S2 US-Plug - 115V/60HZ offers precise and reliable dosing performance for a variety of laboratory and industrial applications. Featuring a robust diaphragm design, this pump ensures accurate chemical dosing with excellent chemical resistance and long service life. The 115V/60HZ power supply with US plug makes it ideal for use in North American facilities.

Key Features:

  • Brand: KNF
  • Model: SIMDOS 10 U FEM 1.10 KT.18S2
  • Voltage & Plug: 115V/60HZ with US plug
  • Type: Diaphragm dosing pump
  • Application: Accurate chemical dosing and fluid transfer
  • Durability: Chemical resistant diaphragm for extended use
  • Packaging: Supplied as a single unit

The KNF SIMDOS 10 pump is a dependable solution for precise dosing tasks in laboratory and industrial environments.

Compare similar models

SIMDOS®10 Diaphragm Dosing Pump U FEM 1.10 KT.18S2 US-Plug - 115V/60HZ

Manufacturer P/N

U167529/160160

Part Number

4.686 742

Manufacturer

KNF

Power supply frequency

60 Hz

SIMDOS®10 membrane dosing pump FEM 1.10 KT.18 S2
Available soon
KNF SIMDOS 10 Membrane Dosing Pump FEM 1.10 KT.18 S2

$3,260.68

Inc. GST

Manufacturer P/N

167523/160160

Part Number

6.268 391

Manufacturer

KNF

Power supply frequency

50/60 Hz

SIMDOS®10 membrane dosing pump FEM 1.10 TT.18 S2
Available soon
KNF SIMDOS 10 Membrane Dosing Pump FEM 1.10 TT.18 S2

$3,492.43

Inc. GST

Manufacturer P/N

167524/160160

Part Number

6.268 393

Manufacturer

KNF

Power supply frequency

50/60 Hz

SIMDOS®10 membrane dosing pump FEM 1.10 FT.18 S2
Available soon
KNF SIMDOS 10 Membrane Dosing Pump FEM 1.10 FT.18 S2

$6,003.97

Inc. GST

Manufacturer P/N

167525/160160

Part Number

6.268 389

Manufacturer

KNF

Power supply frequency

50/60 Hz

SIMDOS®10 Diaphragm Dosing Pump U FEM 1.10 TT.18S2 US-Plug - 115V/60HZ

Manufacturer P/N

U167530/160160

Part Number

4.686 740

Manufacturer

KNF

Power supply frequency

60 Hz

SIMDOS®10 Diaphragm Dosing Pump U FEM 1.10 FT.18S2 US-Plug - 115V/60HZ

Manufacturer P/N

U167531/160160

Part Number

4.686 744

Manufacturer

KNF

Power supply frequency

60 Hz

More items to explore

Chemically-resistant Diaphragm Dosing Pumps SIMDOS® 02, manual control

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU/UK/CHFEM 1.02 TT.18S166072/1654679.880 567$3,485.25
EU/UK/CHFEM 1.02 ST.18S166259/1654677.643 148$7,369.33
EU/UK/CHFEM 1.02 KT.18S166071/1654679.880 565$3,251.70
EU/UK/CHFEM 1.02 FT.18S164970/1654679.880 569$5,987.80
USU FEM 1.02 TT.18SU166072/1654674.686 748$4,760.78
USU FEM 1.02 KT.18SU166071/1654674.686 747$4,442.79
USU FEM 1.02 FT.18SU164970/1654674.686 746$8,184.95

Chemically-resistant Diaphragm Dosing Pumps SIMDOS® 10, external control

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU/UK/CHFEM 1.10 TT.18RCP2167222/1601606.285 974$4,548.79
EU/UK/CHFEM 1.10 KT.18RCP2167047/1601606.310 685$4,320.63
EU/UK/CHFEM 1.10 FT.18RCP2167042/1601606.274 454$7,067.51
EU/UK/CHFEM 1.10 ST.18RCP2167204/1601606.313 297$8,874.81
USU FEM 1.10 FT.18RCP2U167040/1601604.686 745$9,440.71
USU FEM 1.10 KT.18RCP2U167045/1601604.686 743$5,908.75
USU FEM 1.10 TT.18RCP2U167221/1601604.686 741$6,224.94

Frequently asked questions

It offers precise and reliable dosing performance for a variety of laboratory and industrial applications. Featuring a robust diaphragm design, this pump ensures accurate chemical dosing with excellent chemical resistance and long service life. The 115V/60HZ power supply with US plug makes it ideal for use in North American facilities.

Insights

Explore
Burette vs Pipette: Key Differences and Which to Use

4 mins read

Burette vs Pipette: Key Differences and Which to Use

This guide explains the practical difference between a burette and a pipette, two instruments that are often confused because both dispense measured volumes of liquid, but that are built for genuinely different jobs. It breaks down how a burette's stopcock and full-length graduated scale let an operator dispense a variable, watched volume and stop the instant a reaction reaches its endpoint, versus how a pipette (volumetric, graduated or micropipette) is built to transfer one known or pre-set volume in a single action. Rather than presenting the two as competing options, the piece frames them as complementary tools tied to different steps in a procedure: burettes for titration and any reaction where the target volume isn't known in advance, pipettes for sample preparation, dilutions and any step where the volume is already fixed.

Read full story
Top 5 Brands for Graduated Cylinders in 2026

4 mins read

Top 5 Brands for Graduated Cylinders in 2026

This guide compares the five graduated cylinder brands most commonly used across Australian laboratories: Hirschmann Laborgeräte (DURAN® glass), Kartell (PMP plastic), ISOLAB Laborgeräte, BRAND (BLAUBRAND®) and VITLAB. Rather than treating graduated cylinders as interchangeable, it breaks down what actually separates them, Class A versus Class B accuracy tolerances, glass versus plastic construction, base stability and certification standards such as USP conformity, and explains which of these differences genuinely matter depending on the work.

Read full story
Top 5 Brands for Erlenmeyer Flasks in 2026

4 mins read

Top 5 Brands for Erlenmeyer Flasks in 2026

This guide compares the five Erlenmeyer flask brands most commonly used across Australian laboratories today: DWK Life Sciences (DURAN®), ISOLAB Laborgeräte, LLG Labware, BRAND and Kartell. Rather than treating all Erlenmeyer flasks as interchangeable, it breaks down what actually separates them in practice, wall thickness consistency, thermal shock resistance, neck and closure compatibility, and material choice between borosilicate glass and polypropylene, and explains which of these differences matter for which kind of lab work.

Read full story